Site IDSiteLocationCityCountyEFO Name
89009Johnny Bold's Garage AKA Ryder Truck Rental AKA W-5 AKA R-4 AKA E. L. MORGAN (WHITEHALL ROAD) 709 WhitehallJacksonMadisonJackson

Permit Information

TNG830261
UST
Active
ATC Group Services, LLC
Johnny Bolds Garage
The groundwater is filtered through an oil/water separator, then treated by a 15 gallon per minute capacity air stripper, then filtered through bag filters and finally polished with activated carbon prior to being discharged.
N/A
30-NOV-2023
30-NOV-2023
30-NOV-2023
30-NOV-2023
01-DEC-2023
30-SEP-2028
Anderson Branch from Outfall 001
Qw = 15 GPM*60*24/1000000 = 0.022 MGD Qs = 0.043 CFS *0.6264 = 0.027 MGD. DF = (Qs+ Qw) / Qw = 2.22
Liquid ring vacuum extraction pump followed by a shallow tray air stripper and a granular activated carbon polishing filters.
5541
.022
30-NOV-2023 12:36PM

Other DWR permits at this site

No other permits found.

Permit Documents

View
Notice of Coverage (NOC)Notice of Coverage (NOC) 202330-NOV-2023
Notice of Coverage (NOC)Notice of Coverage Johnny Bolds Garage14-JAN-2020
Notice of Intent (NOI)Notice on Intent Johnny Bolds Garage13-JAN-2020
Forms submitted through MyTDEC Forms after 11/17/2020 will be available in FileNet.

Inspections

no data found