Skip to Main Content

Parent Site

Site IDSiteLocationCityCountyEFO NameGIS
5057Knoxville Utilities Board (KUB) - Loves Creek Wastewater Treatment Plant (STP)5760 Sandis LaneKnoxvilleKnoxKnoxvilleView Map

Permit Information

TN0021822
Individual
Reissuance
Knoxville Utilities Board (KUB)
Loves Creek STP
treatment of municipal wastewater with activated sludge process
M
M
MW
23-MAY-2024
29-MAY-2024
25-JUN-2024
01-OCT-2019
01-DEC-2019
30-NOV-2024
Holston River Mile 5.0
treated municipal wastewater from Outfall 001
Activated sludge system using UV light disinfection with hypochlorite backup systems. Waste Activated Sludge (WAS) at the treatment plant is sent to the Kuwahee treatment plant through the sewer collection system.
4952
10.3
08-JUL-2024 03:41PM

Other DWR permits at this site

  • 1 - 2 of 2
Permit NoPermittee NameProject NamePermit TypeStatusRatingEFO Name__Issuance___Effective___Expiration__
TNR056407KUB - Loves Creek WWTP-TMSPActiveN/AKnoxville19-JUL-202020-JUL-202030-JUN-2025
TNB021822KUB Loves Creek STP-BiosolidsInactiveN/AKnoxville---
  • 1 - 2 of 2

Permit Documents

View
Email 19.0177 E-mail String09-APR-2019
Letter16-0552 Plans Approval Letter29-JUL-2016
Letter16_0552 Plans Cover Letter12-JUL-2016
Letter17_0350 Plans Approval Letter08-AUG-2017
Letter19-0418 Ref14-AUG-2019
Letter19.0031 Approval letter13-FEB-2019
Environmental Review19.0031 Ref16-JAN-2019
Letter19.0418 Letter14-AUG-2019
Form20.0648 Fee Worksheet26-OCT-2020
Letter20.0661 Letter30-NOV-2020
Forms submitted through MyTDEC Forms after 11/17/2020 will be available in FileNet.

Inspections

26-JUL-2023Compliance Eval (non-sampling) (CEI)In Compliance
29-APR-2022Compliance Eval (non-sampling) (CEI)In Compliance
11-AUG-2021Compliance Eval (non-sampling) (CEI)In Compliance
18-DEC-2019Compliance Eval (non-sampling) (CEI)In Compliance
13-DEC-2017Compliance Eval (non-sampling) (CEI)In Compliance
20-SEP-2016Compliance Eval (non-sampling) (CEI)In Compliance
06-AUG-2013Compliance Eval (non-sampling) (CEI)In Compliance
08-DEC-2008Compliance Eval (non-sampling) (CEI)Not Complete and/or Stable
14-NOV-2006Reconnaissance (RI)In Compliance

Wastewater Engineering Plans Review

23.0329ApprovedCDMJB6/22/20237/13/2023UGC - 204 Branch Lane
23.0125ApprovedCDA. Bahour3/8/20233/17/2023KUB - Crystal Lake Drive 6915 - LPS
22.0780ApprovedCDCourtlandV3/13/20233/31/2023Holston Hills Pump Station Rehabilitation Project
22.0519ApprovedCDA. Bahour3/3/20233/9/2023KUB - Pinnacle Dr 5305 - LPS
22.0462ApprovedCDTNH10/10/202210/12/2022Lyon's Creek Force Main Upsizing
21.0764ApprovedCDTNH10/11/202110/25/2021UGC - Elna Marie Dr 7035
20.0734ApprovedCDTNH12/10/20201/5/2021Wayland Road Pump Station
20.0661ApprovedCDMNU11/2/202011/30/20201544 Cliffside Lane
20.0648InactiveCDMJB10/26/2020-Ault Road Sewer Extension
19.0418ApprovedCDMNU7/16/20198/14/2019110 S Rich Road Low Pressure Sewer Design