Skip to Main Content
DataViewer - Division of Water Resources (DWR)
Page Help
GUEST
---
Go to Home Page
Home
Permits
Permits on Public Notice
Permits on Public Notice (Map)
Moratoriums
Permit Types
Permitting Actions
Permit Appeals
Documents
Complaints
Inspections
Engineering Plans
Sewage Works
Public Water Systems
Hydrologic Determinations
Exceptional Waters
Ambient Monitoring
Ambient Monitoring Stations
Surface Waters Chemical Data
Tissue Monitoring Data
Habitat Assessments
SQSH Data
QLP Data
Oil & Gas Wells
Water Wells
Licensed Drillers
Driller Report
Notices of Intent
Certified Operators
Septic Systems
Active Pumpers and Installers
Home
DWR Permits
Permit Information
Parent Site
Site ID
Site
Location
City
County
EFO Name
2119
Collegedale Collection System
office located at 9751 Sanborn Drive, Collegedale, TN 37315-1880
Collegedale
Hamilton
Chattanooga
Permit Information
Permit Number
SOP-89136
Permit Type
SOP
Status
Reissuance
Permittee Name
City of Collegedale
Project Name
Municipal Collection System
Activity Description
Sewage collection system to the City of Chattanooga sewerage system
Permit Rating
N/A
Facility Classification
M
Discharge Code
CS
Application Received
12-FEB-2020
Application Returned
Application Complete
14-FEB-2020
Public Notice Date
23-JUN-2020
Issuance Date
03-AUG-2020
Effective Date
01-SEP-2020
Expiration Date
31-AUG-2025
Modification Date
Termination Date
Receiving Stream
N/A
Effluent Description
No discharge allowed
Treatment Description
Sewage collection system to Chattanooga STP
SIC Code
4952
SIC 2
SIC 3
SIC 4
Design Flow Rate [MGD]
2.16
Record Last Updated
16-SEP-2024 03:14PM
Other DWR permits at this site
Go
Actions
No other permits found.
Column Actions
Search
Permit Documents
Search All Documents
View Permit
FileNet Documents
View
File Type
Description
Document Date
Report
Q3 2024 report
14-OCT-2024
Memo
WPN24.0544 ARP Memo 20240806
06-AUG-2024
Report
Q2 2024 report
11-JUL-2024
Letter
24.0371 Approval letter 20240628
28-JUN-2024
Letter
23.0516R Approval letter 20240626
26-JUN-2024
Report
Q1 2024 report
11-APR-2024
Letter
23.0633 Approval letter 20240223
23-FEB-2024
Letter
WPN23.0809 Approval Letter 20240129
29-JAN-2024
Report
Q4 2023 report
11-JAN-2024
Report
2023 Annual report
11-JAN-2024
row(s) 1 - 10 of 156
Next
Forms submitted through MyTDEC Forms after 11/17/2020 will be available in FileNet.
Moratorium
Problem
Mechanism
Result
Action Date
Status
Percent Annual I I
Chronic Overflows
Letter
Chronic overflows from manhole #526. Moratorium initiated in 2016. In reviewing a plan design, it was discovered that the manhole referenced in the following moratorium is no longer in service, so this moratorium is no longer in effect. Per the design engineer for the project under review, “Regarding manhole 526, that was a manhole located outside of our pump station, which was abandoned and is no longer in service. While overflows may have previously existed, these occurred when WWTA’s Lee Highway Pump Station was connected to ours. Since their connection to our station was eliminated within the last few years, we have experienced no overflows in our system.” From Matthew Tipton to Bob O'Dette 9/13/2023
5/2/2019
Watch List
Inspections
Inspection Date
Type
Result
07-NOV-2022
Compliance Evaluations (non-NPDES)
In Compliance
31-JUL-2017
Compliance Evaluations (non-NPDES)
In Compliance
01-JAN-2016
Compliance Evaluations (non-NPDES)
Out of Compliance
row(s) 1 - 3 of 3
Wastewater Engineering Plans Review
Project no
Plans Status
Type
Reviewer
Date Received
Approved Date
Project Name
13.0594
Approved
LINE
MNU
9/20/2013
10/17/2013
Integra Preserve
15.0281
Approved
LINE
MNU
4/30/2015
6/3/2015
Hawthorne at the Summit Apartments
15.0278
Approved
LINE
MNU
4/30/2015
6/4/2015
Collegedale Station Main Entry Road
15.0274
Approved
LINE
MNU
4/27/2015
6/9/2015
Apison Pike Road Improvements, Phasee 2
15.0162
Approved
LINE
A. Bahour
8/28/2015
9/8/2015
David Wall Sewer Extension
17.0128
Approved
LINE
A. Bahour
2/14/2017
2/16/2017
Shadow Creek - Revised
17.0165
Approved
LINE
MNU
2/27/2017
3/15/2017
White Oak Drive
17.0475
Approved
LINE
MNU
7/21/2017
8/7/2017
Shadow Creek S/D
17.0545
Approved
LINE
A. Bahour
8/16/2017
9/8/2017
SAU Student Center
17.0743
Approved
LINE
A. Bahour
12/18/2017
12/21/2017
Written Media Headquarters - Southern Adventist University
row(s) 1 - 10 of 29