Compliance Eval (non-sampling) (CEI)
Minor Deficiency Noted
¿ Masses of sewage debris have accumulated on structures in the oxidation ditches allowing woody vegetation to take root. These masses must be removed. Additionally, routine cleaning procedures must be implemented to ensure that these masses or not allowed to accumulate again.
¿ The wooden staircase allowing access to Frey Branch has decayed and is unsafe. This staircase should be either repaired or another path for access should be established.
¿ The procedure for dissolved oxygen meter calibration should be examined to ensure that proper air calibration is being done.
¿ Recordkeeping that documents sewage overflows should be improved to ensure that all overflow events are properly reported. This inspection revealed an overflow event at the Meadowlark pump station that was not reported to this office.