Skip to Main Content
Site IDParent SiteLocationCountyEFO
114642Morganton Park (Preston Park)2127 Morganton RoadBlountKnoxville

Inspection Details

59925
114642
TNR135110
1/5/2018
Stormwater Construction Non-Sampling
Out of Compliance
No documentation on-site. Unable to determine whether or not more than 50 acres have been disturbed. Both temporary stream crossings have large amounts of sediment that have discharged into the streams. No stabilization efforts made up-slope of the culverts. Inadequate erosion control measures at both crossings and throughout the site. Small corrugated plastic pipes are setup to drain water from the top of the crossings then down into the streams without any treatment of the sediment laden water. There are areas of silt fence down/buried with sediment leaving the construction site. Seed and straw has been installed recently on the front portion of the site, off Morganton Road. No sediment basins or detention ponds were observed.