6/20/2018
Stormwater Construction Non-Sampling
Out of Compliance
The original approved SWPPP stated this project will be completed in 2 phases, phase 1 consisting of 47.8 acres and phase 2 consisting of 12.5 acres which will as soon as phase 1 is stabilized. Both phase 1 and 2 are active resulting in greater than 50 acres disturbed. Greater than 20 acres have been inactive and unstable for over 2 months with steep s slopes in multiple areas. This has resulted in sediment discharge off-site. Multiple EPSCS/BMPs are missing for both phase 1 and 2. No site assessment has been conducted throughout the life of this project. City of Maryville has sent multiple NOVs and a Stop Work Order.
Both temporary stream crossings have been removed and hydro-seed used for stabilization for ARAP NR1803.037. ARAP NR1703.133 has not been started.