5169Nashville Whites Creek STP1360 County Hospital RoadDavidsonNashville

Inspection Details

34726
5169
TN0024970
2/27/2013
Compliance Sampling (CSI)
NOV
PAI was performed 2/24/12 for Nashville Central STP. The PAI letter was provided to Whites Crk and Dry Crk STP's. I chose to conduct a Compliance sampling inspection (CSI) on 2/27-28/13. At the White's Crk plant, the pH and DO meters were improperly calibrated. Therefore, previously submitted data is invalid. Not all the tubing (3 sections) for the samplers were changed monthly. The sample containers were cleaned with a mult-purpose cleaner not an analytical grade soap. These deficiencies compromise the sample integrity making analytical results invalid. Rec'd last requested information 4/16/13.