Inspection Details
Site ID
Parent Site
Location
County
EFO
161656
Frey Branch Cottages
Wilkinson Ln.
Robertson
Nashville
Inspection Details
Inspection Number
113990
Site ID
161656
Permit Number
NR2104.182
Inspection date
11/21/2023
Inspection type
ARAP Compliance Inspection
Status
Out of Compliance
Notes
Road crossing, although it appears temporary, has not been installed in compliance with the terms of the ARAP. Culvert pipes are significantly above streambed elevation, and the stream at time of inspection is flowing under at least one of the pipe culverts. Leaf and debris pile on the upstream side of the culvert indicates in higher flow events, the pipes are undersized and causing partial impoundment of stream.