Inspection Details
Site ID
Parent Site
Location
County
EFO
177331
Dollar General
W Andrew Johnson Hwy
Greene
Johnson City
Inspection Details
Inspection Number
114652
Site ID
177331
Permit Number
TNR162319
Inspection date
2/13/2024
Inspection type
Stormwater Construction Non-Sampling
Status
Out of Compliance
Notes
At construction entrance, missing silt fence/EPSC measures have allowed untreated water containing sediment to migrate off site. The boundary of disturbance has been exceeded at the southwestern, northern and eastern area of the site. Construction entrance needed reinforcement with additional larger grade gravel laid down. Silt fence needed to be extended to the road adjacent of construction entrance and on the west side of the site all the way back to northern edge of area of disturbance boundary. Sections of silt fence were damaged and down. Areas behind silt fence with more than 50% buildup of sediment. The last inspection report was for 1-25-2024.