Qualifier --- Description
B --- Detection in blank
BH --- Detection in blank. Holding time exceeded.
BU --- Detection in blank. Not Detected: The analyte was analyzed for, but was not detected at a level greater than or equal to the level of the adjusted Contract Required Quantitation Limit (CRQL) for sample and method.
D --- Contract Required Quantitation Limit (CRQL) not met due to sample matrix interference, dilution required.
DB --- Contract Required Quantitation Limit (CRQL) not met due to sample matrix interference, dilution required. Detection in blank.
DH --- Contract Required Quantitation Limit (CRQL) not met due to sample matrix interference, dilution required. Holding time exceeded
DJ --- Contract Required Quantitation Limit (CRQL) not met due to sample matrix interference, dilution required. Estimated:The analyte was positively identified and the associated numerical value is the approximate concentration of the analyte in the sample.
DR --- Contract Required Quantitation Limit (CRQL) not met due to sample matrix interference, dilution required. Rejected: The sample results are unusable due to the quality of the data generated because certain criteria were not met. The analyte may or may not be present in the sample.
DU --- Contract Required Quantitation Limit (CRQL) ... Not Detected: The analyte was analyzed for, but was not detected at a level greater than or equal to the level of the adjusted Contract Required Quantitation Limit (CRQL) for sample and method.
EE --- Identifies compounds whose concentration exceed the calibration range addition of the instrument for that specific analysis.
H --- Holding time exceeded
HBJ --- Holding time exceeded. Detection in blank. Estimated: The analyte was positively identified and the associated numerical value is the approximate concentration of the analyte in the sample.
HL --- Holding time exceeded. Lowest available reporting limit for the analytical method used.
HLBL --- High labeled compound recovery in sample, estimated value, estimated value
HMSR --- High matrix spike recovery, potential high bias
HNRO --- High native analyte recovery in OPR (or LCS), potential high bias
HSSR --- High surrogate spike recovery, potential high bias
HVER --- High calibration verification standard recovery, estimated value
ITNA --- Incubation time not attained
ITNM --- Incubation temperature not maintained
J --- Estimated: The analyte was positively identified and the associated numerical value is the approximate concentration of the analyte in the sample.
J+ --- Estimated: The analyte was positively identified and the associated numerical value... +++.
JB --- Estimated: The analyte was positively identified and the associated numerical value is the approximate concentration of the analyte in the sample. Detection in blank.
JH --- Estimated: The analyte was positively identified and the associated numerical value is the approximate concentration of the analyte in the sample. Holding time exceeded.
JL --- Estimated: The analyte was positively identified and the associated numerical value is the approximate concentration of the analyte in the sample. Lowest available reporting limit for the analytical method used.
KK --- True bacterial concentration is assumed to be less than the reported value.
L --- Lowest available reporting limit for the analytical method used.
LL --- True bacterial concentration is assumed to be greater than the reported value.
LLBL --- low labeled compound recovery in sample, estimated value
LLRO --- low labeled compound recovery in the OPR (or LCS), estimated value
LMSR --- low matrix spike recovery, potential low bias
LNRO --- low native analyte recovery in OPR (or LCS), potential low bias
LOPR --- low OPR (or LCS) recovery, potential low bias
LVER --- low calibration verification standard recovery, potential low bias
MTRX --- possible matrix interference, estimated value
NCNF --- not confirmed or not found, estimated value
NLBL --- no labeled compound recovery in sample, rejected
NLRO --- no labeled compound recovery in OPR (or LCS), rejected
NMSR --- no matrix spike recovery, rejected
NNRO --- no native analyte recovery in OPR (or LCS), rejected
NOPR --- no OPR (or LCS) recovery, rejected
NVER --- no calibration verification standard recovery, rejected
R --- Rejected: The sample results are unusable due to the quality of the data generated because certain criteria were not met. The analyte may or may not be present in the sample.
RMAX --- result is a maximum value
RNAF --- result no affected by noted QC issue
RNF2 --- results of 2 columns not within factor of 2, estimated value
RNON --- result reported as non-detect due to blank contamination
RPDX --- RPD is MS/MSD pair exceeds criterion, estimated value
U --- Not Detected: The analyte was analyzed for, but was not detected at a level greater than or equal to the level of the adjusted Contract Required Quantitation Limit (CRQL) for sample and method.
UH --- Not Detected: The analyte was analyzed for, but was not detected at a level greater than or equal to the level of the adjusted Contract Required Quantitation Limit (CRQL) for sample and method. Holding time exceeded.
UJ --- Not Detected/Estimated: The analyte was not detected at a level greater than or equal to the adjusted CRQL or the reported adjusted CRQL is approximate and may be inaccurate or imprecise.