Skip to Main Content
DataViewer - Division of Water Resources (DWR)
Page Help
Guest
---
Go to Home Page
Driller Report Summary
Back
Print
WELL NUMBER
Well Number
20242885
Driller Tag Number
D0132152
Inspection Tag Number
-
Date Received
11/08/2024
WELL CONTRACTOR
License Number
698
Driller Name
Kenneth Warren Gentry
Rig Operator
STEPHEN KEENER
WELL LOCATION
County Name
LEWIS
Driller Map No.
-
Quad Name
GORDONSBURG
Quad Number
0050SW
Quad Nth
6
Address
164 LOVEMAN LN
Address Line 2
-
City Name
HAMPSHIRE
State Name
Tennessee
Zip
38461
Zip Ext
-
Distance From Landmark (miles)
-
Direction From Landmark
-
Nearest Landmark
-
Latitude
35.5808421
Longitude
-87.385008
TYPE OF WORK
Date Drill Rig Left Site
07/22/2024
Type of Work
New Well
WELL COMPLETION DATA
Completion Date
07/22/2024
Total Depth (ft-bgs)
300
Depth To Bedrock (ft)
146
Static Level (ft-bgs)
-
Estimated Yield (GPM)
2
WATER-BEARING ZONES
Depth (ft-bgs)
GPM
GPH
Water Quality
134
2
-
cloudy
WELL TEST
Tested By
Blowing
Static Level (ft-bgs)
-
Pumping Level (ft-bgs)
-
Test After Hours
-
Test After Mins
-
Test Yield (GPM)
2
Hours Prior to Test
1
Minutes Prior to Test
-
FORMATION LOG
Depth from (ft)
Depth to (ft)
Description
0
8
CHERT BIG ROCKS GRAVEL
8
47
CLAY GRAVEL
47
80
TIGHT RED CLAY
80
134
CLAY SEAMS GRAVEL
134
146
BROKEN ROCK GRAVEL
146
230
LS DARK HARD
230
300
LS MEDIUM TO DARK SOFT
WELL OWNER INFORMATION
Company Name
-
Owner Name
BECKY SCHRANK
Address
P O BOX 516
Address (Line 2)
-
City
HOHENWALD
State
Tennessee
Zip Code
38462
PROPOSED USE OF WELL
Well Use
Residential
PRIMARY CASING
Diameter (in)
6
Top Set (in-above ground)
12
Primary Casing Depth (ft-bgs)
134
Primary Casing Type
Steel
Wall Thickness
.188
SDR#
-
WELL FINISH
Well Finish
Slotted
From (ft-bgs)
134
To (ft-bgs)
147
Screen Type
-
Slot Size (in)
-
Gravel Pack From (ft-bgs)
134
Gravel Pack To (ft-bgs)
168
BACK FILL MATERIAL
Back Fill Type
From (ft-bgs)
To (ft-bgs)
Bentonite
3
10
Cuttings
10
134
LINER CASING
Type
-
Diameter (in)
-
From (ft-bgs)
-
To (ft-bgs)
-
Packers Installed?
-
Packer 1 Depth (ft-bgs)
-
Packer 2 Depth (ft-bgs)
-
ANTICIPATED WATER QUALITY
Appearance
Clear
Taste
Good
Odor
-
Other
-
GENERAL INFORMATION
Well Disinfected?
Y
Well Capped?
Y
50ft From Septic System?
-
Septic Distance Provided By
Driller Determination
Drilling Process Water Obtained From
Well
Pump Installed By Driller?
-
COMMENTS
Comments
43378