Skip to Main Content
DataViewer - Division of Water Resources (DWR)
Page Help
Guest
---
Go to Home Page
Driller Report Summary
Back
Print
WELL NUMBER
Well Number
20221530
Driller Tag Number
D0124582
Inspection Tag Number
-
Date Received
07/07/2022
WELL CONTRACTOR
License Number
982
Driller Name
Rodney D. Tatum
Rig Operator
TYSON BARNES
WELL LOCATION
County Name
GIBSON
Driller Map No.
2CW
Quad Name
KENTON
Quad Number
0428NE
Quad Nth
8
Address
213 CONOVER NEEDHAM RD
Address Line 2
-
City Name
KENTON
State Name
Tennessee
Zip
38233
Zip Ext
-
Distance From Landmark (miles)
0.41
Direction From Landmark
S
Nearest Landmark
intersection of Morella & Conover Needham Rds
Latitude
36.16472222
Longitude
-89.05833333
TYPE OF WORK
Date Drill Rig Left Site
06/20/2022
Type of Work
New Well
WELL COMPLETION DATA
Completion Date
06/20/2022
Total Depth (ft-bgs)
255
Depth To Bedrock (ft)
-
Static Level (ft-bgs)
80
Estimated Yield (GPM)
20
WATER-BEARING ZONES
Depth (ft-bgs)
GPM
GPH
Water Quality
-
-
-
-
WELL TEST
Tested By
Blowing
Static Level (ft-bgs)
80
Pumping Level (ft-bgs)
-
Test After Hours
1
Test After Mins
-
Test Yield (GPM)
20
Hours Prior to Test
1
Minutes Prior to Test
-
FORMATION LOG
Depth from (ft)
Depth to (ft)
Description
0
5
topsoil
5
20
brown clay
20
30
red clay
30
50
red sand
50
60
white clay
60
125
sand
125
190
gray clay
190
247
coarse white sand
247
255
gray clay
WELL OWNER INFORMATION
Company Name
-
Owner Name
TYSON GREEN
Address
213 CONOVER NEEDHAM RD
Address (Line 2)
-
City
KENTON
State
Tennessee
Zip Code
38233
PROPOSED USE OF WELL
Well Use
Residential
PRIMARY CASING
Diameter (in)
4
Top Set (in-above ground)
6
Primary Casing Depth (ft-bgs)
235
Primary Casing Type
Plastic
Wall Thickness
40
SDR#
-
WELL FINISH
Well Finish
Screen
From (ft-bgs)
235
To (ft-bgs)
255
Screen Type
Plastic
Slot Size (in)
0.01
Gravel Pack From (ft-bgs)
225
Gravel Pack To (ft-bgs)
255
BACK FILL MATERIAL
Back Fill Type
From (ft-bgs)
To (ft-bgs)
Bentonite
3
10
Cuttings
10
235
LINER CASING
Type
None
Diameter (in)
-
From (ft-bgs)
-
To (ft-bgs)
-
Packers Installed?
N
Packer 1 Depth (ft-bgs)
-
Packer 2 Depth (ft-bgs)
-
ANTICIPATED WATER QUALITY
Appearance
Clear
Taste
Good
Odor
-
Other
-
GENERAL INFORMATION
Well Disinfected?
Y
Well Capped?
Y
50ft From Septic System?
Y
Septic Distance Provided By
Driller Determination
Drilling Process Water Obtained From
Well
Pump Installed By Driller?
N
COMMENTS
Comments
no pump test well was developed by blowing