Skip to Main Content

Driller Report Summary

WELL NUMBER

Well Number
20221528
Driller Tag Number
D0124584
Inspection Tag Number
066893
Date Received
07/07/2022

WELL CONTRACTOR

License Number
982
Driller Name
Rodney D. Tatum
Rig Operator
TYSON BARNES

WELL LOCATION

County Name
FAYETTE
Driller Map No.
5DX
Quad Name
MOSCOW-SE
Quad Number
0424SE
Quad Nth
4
Address
2430 COWAN LOOP
Address Line 2
-
City Name
MOSCOW
State Name
Tennessee
Zip
38057
Zip Ext
-
Distance From Landmark (miles)
0.5
Direction From Landmark
E
Nearest Landmark
Intersection of Moss & Cowan Loop Rds
Latitude
35.08194444
Longitude
-89.33694444

TYPE OF WORK

Date Drill Rig Left Site
06/27/2022
Type of Work
New Well

WELL COMPLETION DATA

Completion Date
06/27/2022
Total Depth (ft-bgs)
160
Depth To Bedrock (ft)
-
Static Level (ft-bgs)
90
Estimated Yield (GPM)
20

WATER-BEARING ZONES

WELL TEST

Tested By
Blowing
Static Level (ft-bgs)
90
Pumping Level (ft-bgs)
-
Test After Hours
1
Test After Mins
20
Test Yield (GPM)
-
Hours Prior to Test
1
Minutes Prior to Test
-

FORMATION LOG

05topsoil
515brown clay
1525sand
2535white clay
35160coarse sand

WELL OWNER INFORMATION

Company Name
-
Owner Name
COLE TRIMM
Address
2430 COWAN LOOP
Address (Line 2)
-
City
MOSCOW
State
Tennessee
Zip Code
38057

PROPOSED USE OF WELL

Well Use
Residential

PRIMARY CASING

Diameter (in)
4
Top Set (in-above ground)
6
Primary Casing Depth (ft-bgs)
140
Primary Casing Type
Plastic
Wall Thickness
40
SDR#
-

WELL FINISH

Well Finish
Screen
From (ft-bgs)
140
To (ft-bgs)
160
Screen Type
Plastic
Slot Size (in)
0.01
Gravel Pack From (ft-bgs)
130
Gravel Pack To (ft-bgs)
160

BACK FILL MATERIAL

Bentonite310
Cuttings10130

LINER CASING

Type
None
Diameter (in)
-
From (ft-bgs)
-
To (ft-bgs)
-
Packers Installed?
N
Packer 1 Depth (ft-bgs)
-
Packer 2 Depth (ft-bgs)
-

ANTICIPATED WATER QUALITY

Appearance
Clear
Taste
Good
Odor
-
Other
-

GENERAL INFORMATION

Well Disinfected?
Y
Well Capped?
Y
50ft From Septic System?
Y
Septic Distance Provided By
Driller Determination
Drilling Process Water Obtained From
Well
Pump Installed By Driller?
N

COMMENTS

Comments
no pump test well was developed by blowing