Skip to Main Content
DataViewer - Division of Water Resources (DWR)
Page Help
Guest
---
Go to Home Page
Driller Report Summary
Back
Print
WELL NUMBER
Well Number
20221525
Driller Tag Number
D0124586
Inspection Tag Number
-
Date Received
07/07/2022
WELL CONTRACTOR
License Number
982
Driller Name
Rodney D. Tatum
Rig Operator
TYSON BARNES
WELL LOCATION
County Name
HARDEMAN
Driller Map No.
3BY
Quad Name
WHITEVILLE
Quad Number
0431SW
Quad Nth
9
Address
2850 UNION SPRINGS RD
Address Line 2
-
City Name
WHITEVILLE
State Name
Tennessee
Zip
38075
Zip Ext
-
Distance From Landmark (miles)
2.75
Direction From Landmark
S
Nearest Landmark
intersection of Hwy 64 & Union Springs Rd
Latitude
35.2825
Longitude
-89.16111111
TYPE OF WORK
Date Drill Rig Left Site
06/28/2022
Type of Work
New Well
WELL COMPLETION DATA
Completion Date
06/28/2022
Total Depth (ft-bgs)
180
Depth To Bedrock (ft)
10
Static Level (ft-bgs)
95
Estimated Yield (GPM)
-
WATER-BEARING ZONES
Depth (ft-bgs)
GPM
GPH
Water Quality
-
-
-
-
WELL TEST
Tested By
Blowing
Static Level (ft-bgs)
95
Pumping Level (ft-bgs)
-
Test After Hours
1
Test After Mins
10
Test Yield (GPM)
-
Hours Prior to Test
1
Minutes Prior to Test
-
FORMATION LOG
Depth from (ft)
Depth to (ft)
Description
0
5
topsoil
5
15
brown clay
15
20
white clay
20
60
medium grain sand
60
180
coarse gray sand
WELL OWNER INFORMATION
Company Name
-
Owner Name
HOUSTON MURPHY
Address
2850 UNION SPRINGS RD
Address (Line 2)
-
City
WHITEVILLE
State
Tennessee
Zip Code
38075
PROPOSED USE OF WELL
Well Use
Residential
PRIMARY CASING
Diameter (in)
4
Top Set (in-above ground)
6
Primary Casing Depth (ft-bgs)
170
Primary Casing Type
Plastic
Wall Thickness
40
SDR#
-
WELL FINISH
Well Finish
Screen
From (ft-bgs)
170
To (ft-bgs)
180
Screen Type
Plastic
Slot Size (in)
0.01
Gravel Pack From (ft-bgs)
160
Gravel Pack To (ft-bgs)
180
BACK FILL MATERIAL
Back Fill Type
From (ft-bgs)
To (ft-bgs)
Bentonite
3
10
Cuttings
10
160
LINER CASING
Type
None
Diameter (in)
-
From (ft-bgs)
-
To (ft-bgs)
-
Packers Installed?
N
Packer 1 Depth (ft-bgs)
-
Packer 2 Depth (ft-bgs)
-
ANTICIPATED WATER QUALITY
Appearance
Clear
Taste
Good
Odor
-
Other
-
GENERAL INFORMATION
Well Disinfected?
Y
Well Capped?
Y
50ft From Septic System?
Y
Septic Distance Provided By
Driller Determination
Drilling Process Water Obtained From
Well
Pump Installed By Driller?
N
COMMENTS
Comments
no pump test well was developed by blowing