Skip to Main Content

Driller Report Summary

WELL NUMBER

Well Number
20221524
Driller Tag Number
D0122896
Inspection Tag Number
-
Date Received
07/07/2022

WELL CONTRACTOR

License Number
982
Driller Name
Rodney D. Tatum
Rig Operator
TYSON BARNES

WELL LOCATION

County Name
FAYETTE
Driller Map No.
5AW
Quad Name
COLLIERVILLE
Quad Number
0416SW
Quad Nth
6
Address
1280 FLETCHER DR
Address Line 2
-
City Name
PIPERTON
State Name
Tennessee
Zip
38017
Zip Ext
-
Distance From Landmark (miles)
0.09
Direction From Landmark
E
Nearest Landmark
intersection of Crestover Dr & Fletcher Dr
Latitude
35.0575
Longitude
-89.64194444

TYPE OF WORK

Date Drill Rig Left Site
06/30/2022
Type of Work
New Well

WELL COMPLETION DATA

Completion Date
06/30/2022
Total Depth (ft-bgs)
108
Depth To Bedrock (ft)
-
Static Level (ft-bgs)
60
Estimated Yield (GPM)
20

WATER-BEARING ZONES

WELL TEST

Tested By
Blowing
Static Level (ft-bgs)
60
Pumping Level (ft-bgs)
-
Test After Hours
1
Test After Mins
-
Test Yield (GPM)
20
Hours Prior to Test
1
Minutes Prior to Test
-

FORMATION LOG

05TOPSOIL
525brown clay
2575medium grain sand
75108coarse white sand

WELL OWNER INFORMATION

Company Name
-
Owner Name
ANDREW OLNEY
Address
1280 FLETCHER DR
Address (Line 2)
-
City
PIPERTON
State
Tennessee
Zip Code
38017

PROPOSED USE OF WELL

Well Use
Residential

PRIMARY CASING

Diameter (in)
4
Top Set (in-above ground)
6
Primary Casing Depth (ft-bgs)
88
Primary Casing Type
Plastic
Wall Thickness
40
SDR#
-

WELL FINISH

Well Finish
Screen
From (ft-bgs)
88
To (ft-bgs)
108
Screen Type
Plastic
Slot Size (in)
0.01
Gravel Pack From (ft-bgs)
78
Gravel Pack To (ft-bgs)
108

BACK FILL MATERIAL

Bentonite310
Cuttings1078

LINER CASING

Type
None
Diameter (in)
-
From (ft-bgs)
-
To (ft-bgs)
-
Packers Installed?
N
Packer 1 Depth (ft-bgs)
-
Packer 2 Depth (ft-bgs)
-

ANTICIPATED WATER QUALITY

Appearance
Clear
Taste
Good
Odor
-
Other
-

GENERAL INFORMATION

Well Disinfected?
Y
Well Capped?
Y
50ft From Septic System?
Y
Septic Distance Provided By
Driller Determination
Drilling Process Water Obtained From
Well
Pump Installed By Driller?
N

COMMENTS

Comments
no pump test well was developed by blowing