Skip to Main Content

Driller Report Summary

WELL NUMBER

Well Number
20243028
Driller Tag Number
D0132470
Inspection Tag Number
-
Date Received
11/18/2024

WELL CONTRACTOR

License Number
982
Driller Name
Rodney D. Tatum
Rig Operator
TYSON BARNES

WELL LOCATION

County Name
GIBSON
Driller Map No.
-
Quad Name
DYER
Quad Number
0436SW
Quad Nth
9
Address
32 IDA WHITE RD
Address Line 2
-
City Name
TRENTON
State Name
Tennessee
Zip
38382
Zip Ext
-
Distance From Landmark (miles)
0.07
Direction From Landmark
W
Nearest Landmark
intersection of Charlie Lewis Rd & Ida White Rd
Latitude
36.0105469
Longitude
-88.8947061

TYPE OF WORK

Date Drill Rig Left Site
10/16/2024
Type of Work
New Well

WELL COMPLETION DATA

Completion Date
10/16/2024
Total Depth (ft-bgs)
160
Depth To Bedrock (ft)
-
Static Level (ft-bgs)
75
Estimated Yield (GPM)
10

WATER-BEARING ZONES

WELL TEST

Tested By
Blowing
Static Level (ft-bgs)
75
Pumping Level (ft-bgs)
-
Test After Hours
1
Test After Mins
-
Test Yield (GPM)
10
Hours Prior to Test
1
Minutes Prior to Test
-

FORMATION LOG

05TOPSOIL
515BROWN CLAY
1535RED SAND
3540WHITE CLAY
4050SAND
5055SANDSTONE
5580SAND AND WHITE CLAY
80118GRAY CLAY AND SAND
118140COARSE SAND AND WHITE CLAY
140160COARSE SAND

WELL OWNER INFORMATION

Company Name
-
Owner Name
GENEVIEVE NEWMAN- HARMAN
Address
32 IDA WHITE ROAD
Address (Line 2)
-
City
TRENTON
State
Tennessee
Zip Code
38382

PROPOSED USE OF WELL

Well Use
Residential

PRIMARY CASING

Diameter (in)
4
Top Set (in-above ground)
6
Primary Casing Depth (ft-bgs)
140
Primary Casing Type
Plastic
Wall Thickness
40
SDR#
-

WELL FINISH

Well Finish
Screen
From (ft-bgs)
140
To (ft-bgs)
160
Screen Type
-
Slot Size (in)
0.01
Gravel Pack From (ft-bgs)
130
Gravel Pack To (ft-bgs)
160

BACK FILL MATERIAL

Bentonite310
Cuttings10130

LINER CASING

Type
-
Diameter (in)
-
From (ft-bgs)
-
To (ft-bgs)
-
Packers Installed?
-
Packer 1 Depth (ft-bgs)
-
Packer 2 Depth (ft-bgs)
-

ANTICIPATED WATER QUALITY

Appearance
Clear
Taste
Good
Odor
-
Other
-

GENERAL INFORMATION

Well Disinfected?
Y
Well Capped?
Y
50ft From Septic System?
Y
Septic Distance Provided By
Driller Determination
Drilling Process Water Obtained From
Well
Pump Installed By Driller?
N

COMMENTS

Comments
no pump test well was developed by blowing