WELL NUMBER
Well Number
20242183
Driller Tag Number
D0131565
Inspection Tag Number
-
Date Received
08/30/2024
WELL CONTRACTOR
License Number
1014
Driller Name
J. Brandon Allen
Rig Operator
DAN RYMER
WELL LOCATION
County Name
ROBERTSON
Driller Map No.
-
Quad Name
YOUNGVILLE
Quad Number
0306SE
Quad Nth
5
Address
4889 HANCOCK RD
Address Line 2
-
City Name
SPRINGFIELD
State Name
Tennessee
Zip
37172
Zip Ext
-
Distance From Landmark (miles)
-
Direction From Landmark
-
Nearest Landmark
-
Latitude
36.5622274
Longitude
-86.8069487
TYPE OF WORK
Date Drill Rig Left Site
08/12/2024
Type of Work
New Well
WELL COMPLETION DATA
Completion Date
08/12/2024
Total Depth (ft-bgs)
100
Depth To Bedrock (ft)
34
Static Level (ft-bgs)
35
Estimated Yield (GPM)
5
WATER-BEARING ZONES
Depth (ft-bgs)
GPM
GPH
Water Quality
39
5
-
clear
WELL TEST
Tested By
Blowing
Static Level (ft-bgs)
-
Pumping Level (ft-bgs)
-
Test After Hours
-
Test After Mins
-
Test Yield (GPM)
-
Hours Prior to Test
-
Minutes Prior to Test
-
FORMATION LOG
Depth from (ft)
Depth to (ft)
Description
34
100
DARK GRAY
0
34
RED CLAY
WELL OWNER INFORMATION
Company Name
-
Owner Name
DANIEL SISCO
Address
4889 HANCOCK RD
Address (Line 2)
-
City
SPRINGFIELD
State
Tennessee
Zip Code
37172
PROPOSED USE OF WELL
Well Use
Residential
PRIMARY CASING
Diameter (in)
6
Top Set (in-above ground)
12
Primary Casing Depth (ft-bgs)
41
Primary Casing Type
Galvanized
Wall Thickness
.188
SDR#
-
WELL FINISH
Well Finish
Slotted
From (ft-bgs)
35
To (ft-bgs)
40
Screen Type
-
Slot Size (in)
0.25
Gravel Pack From (ft-bgs)
25
Gravel Pack To (ft-bgs)
41
BACK FILL MATERIAL
Back Fill Type
From (ft-bgs)
To (ft-bgs)
Cuttings
10
15
Bentonite
15
25
LINER CASING
Type
-
Diameter (in)
-
From (ft-bgs)
-
To (ft-bgs)
-
Packers Installed?
N
Packer 1 Depth (ft-bgs)
-
Packer 2 Depth (ft-bgs)
-
ANTICIPATED WATER QUALITY
Appearance
Clear
Taste
-
Odor
-
Other
-
GENERAL INFORMATION
Well Disinfected?
Y
Well Capped?
Y
50ft From Septic System?
Y
Septic Distance Provided By
Driller Determination
Drilling Process Water Obtained From
Public Supply
Pump Installed By Driller?
N
COMMENTS
Comments
-