Skip to Main Content

Driller Report Summary

WELL NUMBER

Well Number
20243024
Driller Tag Number
D0132474
Inspection Tag Number
-
Date Received
11/18/2024

WELL CONTRACTOR

License Number
982
Driller Name
Rodney D. Tatum
Rig Operator
TYSON BARNES

WELL LOCATION

County Name
TIPTON
Driller Map No.
-
Quad Name
MASON
Quad Number
0415NE
Quad Nth
2
Address
649 BRAMMER RD
Address Line 2
-
City Name
MASON
State Name
Tennessee
Zip
38049
Zip Ext
-
Distance From Landmark (miles)
-
Direction From Landmark
-
Nearest Landmark
intersection of Sanford and Brammer Rd
Latitude
35.4911155
Longitude
-89.5661192

TYPE OF WORK

Date Drill Rig Left Site
10/28/2024
Type of Work
New Well

WELL COMPLETION DATA

Completion Date
10/28/2024
Total Depth (ft-bgs)
140
Depth To Bedrock (ft)
-
Static Level (ft-bgs)
50
Estimated Yield (GPM)
10

WATER-BEARING ZONES

WELL TEST

Tested By
Blowing
Static Level (ft-bgs)
50
Pumping Level (ft-bgs)
-
Test After Hours
1
Test After Mins
-
Test Yield (GPM)
10
Hours Prior to Test
1
Minutes Prior to Test
-

FORMATION LOG

05TOP SOIL
520BROWN CLAY
2060SAND WHITE CLAY
60140COARSE WHITE SAND

WELL OWNER INFORMATION

Company Name
-
Owner Name
LOGAN KIRBY
Address
649 BRAMMER ROAD
Address (Line 2)
-
City
MASON
State
Tennessee
Zip Code
38049

PROPOSED USE OF WELL

Well Use
Residential

PRIMARY CASING

Diameter (in)
4
Top Set (in-above ground)
6
Primary Casing Depth (ft-bgs)
120
Primary Casing Type
Plastic
Wall Thickness
40
SDR#
-

WELL FINISH

Well Finish
Screen
From (ft-bgs)
120
To (ft-bgs)
140
Screen Type
Plastic
Slot Size (in)
0.01
Gravel Pack From (ft-bgs)
110
Gravel Pack To (ft-bgs)
140

BACK FILL MATERIAL

Bentonite310
Cuttings10110

LINER CASING

Type
-
Diameter (in)
-
From (ft-bgs)
-
To (ft-bgs)
-
Packers Installed?
-
Packer 1 Depth (ft-bgs)
-
Packer 2 Depth (ft-bgs)
-

ANTICIPATED WATER QUALITY

Appearance
Clear
Taste
Good
Odor
-
Other
-

GENERAL INFORMATION

Well Disinfected?
Y
Well Capped?
Y
50ft From Septic System?
Y
Septic Distance Provided By
Driller Determination
Drilling Process Water Obtained From
Well
Pump Installed By Driller?
N

COMMENTS

Comments
no pump test well was developed by blowing.