Skip to Main Content
DataViewer - Division of Water Resources (DWR)
Page Help
Guest
---
Go to Home Page
Driller Report Summary
Back
Print
WELL NUMBER
Well Number
20241797
Driller Tag Number
D0131054
Inspection Tag Number
-
Date Received
07/24/2024
WELL CONTRACTOR
License Number
982
Driller Name
Rodney D. Tatum
Rig Operator
TYSON BARNES
WELL LOCATION
County Name
FAYETTE
Driller Map No.
-
Quad Name
MOSCOW
Quad Number
0424SW
Quad Nth
8
Address
1725 BETHLEHEM RD
Address Line 2
-
City Name
MOSCOW
State Name
Tennessee
Zip
38057
Zip Ext
-
Distance From Landmark (miles)
1.54
Direction From Landmark
S
Nearest Landmark
intersection of Hwy 57 and Bethleem Rd
Latitude
35.0280624
Longitude
-89.456105
TYPE OF WORK
Date Drill Rig Left Site
06/12/2024
Type of Work
New Well
WELL COMPLETION DATA
Completion Date
06/12/2024
Total Depth (ft-bgs)
178
Depth To Bedrock (ft)
-
Static Level (ft-bgs)
63
Estimated Yield (GPM)
20
WATER-BEARING ZONES
Depth (ft-bgs)
GPM
GPH
Water Quality
-
-
-
-
WELL TEST
Tested By
Blowing
Static Level (ft-bgs)
63
Pumping Level (ft-bgs)
-
Test After Hours
1
Test After Mins
-
Test Yield (GPM)
20
Hours Prior to Test
1
Minutes Prior to Test
-
FORMATION LOG
Depth from (ft)
Depth to (ft)
Description
175
178
GRAY CLAY
120
175
COARSE SAND
80
120
WHITE CLAY
30
60
WHITE CLAY AND SAND
12
30
SAND
5
12
BROWN CLAY
0
80
COARSE SAND
0
5
TOPSOIL
WELL OWNER INFORMATION
Company Name
-
Owner Name
BRAD BARNETT
Address
1725 BETHLEHAM ROAD
Address (Line 2)
-
City
MOSCOW
State
Tennessee
Zip Code
38057
PROPOSED USE OF WELL
Well Use
Residential
PRIMARY CASING
Diameter (in)
4
Top Set (in-above ground)
6
Primary Casing Depth (ft-bgs)
158
Primary Casing Type
Plastic
Wall Thickness
40
SDR#
-
WELL FINISH
Well Finish
Screen
From (ft-bgs)
158
To (ft-bgs)
178
Screen Type
Plastic
Slot Size (in)
0.01
Gravel Pack From (ft-bgs)
148
Gravel Pack To (ft-bgs)
178
BACK FILL MATERIAL
Back Fill Type
From (ft-bgs)
To (ft-bgs)
Bentonite
3
10
Cuttings
10
148
LINER CASING
Type
-
Diameter (in)
-
From (ft-bgs)
-
To (ft-bgs)
-
Packers Installed?
-
Packer 1 Depth (ft-bgs)
-
Packer 2 Depth (ft-bgs)
-
ANTICIPATED WATER QUALITY
Appearance
Clear
Taste
Good
Odor
-
Other
-
GENERAL INFORMATION
Well Disinfected?
Y
Well Capped?
Y
50ft From Septic System?
Y
Septic Distance Provided By
Driller Determination
Drilling Process Water Obtained From
Well
Pump Installed By Driller?
N
COMMENTS
Comments
no pump test well was developed by pumping