WELL NUMBER
Well Number
20241837
Driller Tag Number
D0127031
Inspection Tag Number
-
Date Received
07/29/2024
WELL CONTRACTOR
License Number
703
Driller Name
Aubrey Lynn Phillips
Rig Operator
W PHILLIPS
WELL LOCATION
County Name
CHESTER
Driller Map No.
-
Quad Name
LURAY
Quad Number
0446SE
Quad Nth
8
Address
GREYSTONE COVE
Address Line 2
-
City Name
HENDERSON
State Name
Tennessee
Zip
38340
Zip Ext
-
Distance From Landmark (miles)
0.5
Direction From Landmark
-
Nearest Landmark
Peddyvestal Loop
Latitude
35.5142848
Longitude
-88.5780454
TYPE OF WORK
Date Drill Rig Left Site
05/25/2024
Type of Work
New Well
WELL COMPLETION DATA
Completion Date
05/25/2024
Total Depth (ft-bgs)
65
Depth To Bedrock (ft)
-
Static Level (ft-bgs)
18
Estimated Yield (GPM)
12
WATER-BEARING ZONES
Depth (ft-bgs)
GPM
GPH
Water Quality
-
-
-
-
WELL TEST
Tested By
Pumping
Static Level (ft-bgs)
18
Pumping Level (ft-bgs)
40
Test After Hours
4
Test After Mins
-
Test Yield (GPM)
-
Hours Prior to Test
-
Minutes Prior to Test
-
FORMATION LOG
Depth from (ft)
Depth to (ft)
Description
40
60
BROWN SAND
35
40
GRAY CLAY
10
35
BROWN SAND
0
10
TOPSOIL & RED SAND
WELL OWNER INFORMATION
Company Name
RUSHING CONSTRUCTION
Owner Name
Address
GREYSTONE COVE
Address (Line 2)
-
City
HENDERSON
State
Tennessee
Zip Code
38340
PROPOSED USE OF WELL
Well Use
Residential
PRIMARY CASING
Diameter (in)
4
Top Set (in-above ground)
6
Primary Casing Depth (ft-bgs)
50
Primary Casing Type
Plastic
Wall Thickness
160
SDR#
26
WELL FINISH
Well Finish
Screen
From (ft-bgs)
50
To (ft-bgs)
60
Screen Type
Plastic
Slot Size (in)
0.01
Gravel Pack From (ft-bgs)
45
Gravel Pack To (ft-bgs)
60
BACK FILL MATERIAL
Back Fill Type
From (ft-bgs)
To (ft-bgs)
Bentonite
3
10
Cuttings
10
45
LINER CASING
Type
-
Diameter (in)
-
From (ft-bgs)
-
To (ft-bgs)
-
Packers Installed?
-
Packer 1 Depth (ft-bgs)
-
Packer 2 Depth (ft-bgs)
-
ANTICIPATED WATER QUALITY
Appearance
Clear
Taste
Good
Odor
-
Other
-
GENERAL INFORMATION
Well Disinfected?
Y
Well Capped?
-
50ft From Septic System?
Y
Septic Distance Provided By
Health Department Permit
Drilling Process Water Obtained From
Well
Pump Installed By Driller?
Y
COMMENTS
Comments
DRILLER NOTE: LOST GPS DEVICE used location for lat and long-sr 9/4/24