Skip to Main Content
DataViewer - Division of Water Resources (DWR)
Page Help
Guest
---
Go to Home Page
Driller Report Summary
Back
Print
WELL NUMBER
Well Number
20242883
Driller Tag Number
D0132000
Inspection Tag Number
-
Date Received
11/08/2024
WELL CONTRACTOR
License Number
698
Driller Name
Kenneth Warren Gentry
Rig Operator
JEREMY ADAMS
WELL LOCATION
County Name
GILES
Driller Map No.
-
Quad Name
APPLETON
Quad Number
0059SW
Quad Nth
8
Address
541 POLLOCK HOLLOW RD
Address Line 2
-
City Name
MINOR HILL
State Name
Tennessee
Zip
38473
Zip Ext
-
Distance From Landmark (miles)
-
Direction From Landmark
-
Nearest Landmark
-
Latitude
35.0400044
Longitude
-87.1858253
TYPE OF WORK
Date Drill Rig Left Site
08/26/2024
Type of Work
New Well
WELL COMPLETION DATA
Completion Date
08/26/2024
Total Depth (ft-bgs)
450
Depth To Bedrock (ft)
33
Static Level (ft-bgs)
-
Estimated Yield (GPM)
10
WATER-BEARING ZONES
Depth (ft-bgs)
GPM
GPH
Water Quality
45
0.5
-
clear sulfur
355
9.5
-
clear sulfur
WELL TEST
Tested By
Blowing
Static Level (ft-bgs)
-
Pumping Level (ft-bgs)
-
Test After Hours
-
Test After Mins
-
Test Yield (GPM)
10
Hours Prior to Test
1
Minutes Prior to Test
-
FORMATION LOG
Depth from (ft)
Depth to (ft)
Description
0
33
CHERT
33
120
LIGHT GRAY LIMESTONE
120
140
BLUISH LIMESTONE
140
360
MEDIUM GRAY LIMESTONE
360
420
WHITE TAN LIMESTONE (CARTERS)
420
450
LIGHT GRAY LIMESTONE
WELL OWNER INFORMATION
Company Name
-
Owner Name
CLAUDIO ROMEO
Address
2427 DOUGLAS GEN LANE
Address (Line 2)
-
City
FRANKLIN
State
Tennessee
Zip Code
37064
PROPOSED USE OF WELL
Well Use
Residential
PRIMARY CASING
Diameter (in)
6
Top Set (in-above ground)
12
Primary Casing Depth (ft-bgs)
41
Primary Casing Type
Steel
Wall Thickness
.188
SDR#
-
WELL FINISH
Well Finish
Open Hole
From (ft-bgs)
41
To (ft-bgs)
450
Screen Type
-
Slot Size (in)
-
Gravel Pack From (ft-bgs)
-
Gravel Pack To (ft-bgs)
-
BACK FILL MATERIAL
Back Fill Type
From (ft-bgs)
To (ft-bgs)
Bentonite
3
10
Cuttings
10
41
LINER CASING
Type
-
Diameter (in)
-
From (ft-bgs)
-
To (ft-bgs)
-
Packers Installed?
-
Packer 1 Depth (ft-bgs)
-
Packer 2 Depth (ft-bgs)
-
ANTICIPATED WATER QUALITY
Appearance
Clear
Taste
-
Odor
Sulphur
Other
-
GENERAL INFORMATION
Well Disinfected?
Y
Well Capped?
Y
50ft From Septic System?
Y
Septic Distance Provided By
Driller Determination
Drilling Process Water Obtained From
Well
Pump Installed By Driller?
-
COMMENTS
Comments
43356