Skip to Main Content
DataViewer - Division of Water Resources (DWR)
Page Help
Guest
---
Go to Home Page
Driller Report Summary
Back
Print
WELL NUMBER
Well Number
20221534
Driller Tag Number
D0124590
Inspection Tag Number
-
Date Received
07/07/2022
WELL CONTRACTOR
License Number
982
Driller Name
Rodney D. Tatum
Rig Operator
TYSON BARNES
WELL LOCATION
County Name
HAYWOOD
Driller Map No.
5AX
Quad Name
STANTON
Quad Number
0423NW
Quad Nth
2
Address
1302 HWY 179
Address Line 2
-
City Name
STANTON
State Name
Tennessee
Zip
38069
Zip Ext
-
Distance From Landmark (miles)
0.26
Direction From Landmark
E
Nearest Landmark
intersection of Wesley & Charleston (Hwy 179) Rds
Latitude
352833
Longitude
892519
TYPE OF WORK
Date Drill Rig Left Site
06/15/2022
Type of Work
New Well
WELL COMPLETION DATA
Completion Date
06/15/2022
Total Depth (ft-bgs)
220
Depth To Bedrock (ft)
-
Static Level (ft-bgs)
75
Estimated Yield (GPM)
40
WATER-BEARING ZONES
Depth (ft-bgs)
GPM
GPH
Water Quality
-
-
-
-
WELL TEST
Tested By
Blowing
Static Level (ft-bgs)
75
Pumping Level (ft-bgs)
-
Test After Hours
1
Test After Mins
-
Test Yield (GPM)
40
Hours Prior to Test
1
Minutes Prior to Test
-
FORMATION LOG
Depth from (ft)
Depth to (ft)
Description
0
5
topsoil
5
15
brown clay
15
18
sandstone
18
80
gray clay
80
115
medium grain sand
115
145
gray clay
145
220
coarse gray sand
WELL OWNER INFORMATION
Company Name
SOUTHERN CONCRETE
Owner Name
Address
860 WESTOVER RD
Address (Line 2)
-
City
JACKSON
State
Tennessee
Zip Code
38305
PROPOSED USE OF WELL
Well Use
Commercial
PRIMARY CASING
Diameter (in)
4
Top Set (in-above ground)
6
Primary Casing Depth (ft-bgs)
190
Primary Casing Type
Plastic
Wall Thickness
40
SDR#
-
WELL FINISH
Well Finish
Screen
From (ft-bgs)
190
To (ft-bgs)
220
Screen Type
Plastic
Slot Size (in)
0.01
Gravel Pack From (ft-bgs)
180
Gravel Pack To (ft-bgs)
220
BACK FILL MATERIAL
Back Fill Type
From (ft-bgs)
To (ft-bgs)
Bentonite
3
10
Cuttings
10
180
LINER CASING
Type
None
Diameter (in)
-
From (ft-bgs)
-
To (ft-bgs)
-
Packers Installed?
N
Packer 1 Depth (ft-bgs)
-
Packer 2 Depth (ft-bgs)
-
ANTICIPATED WATER QUALITY
Appearance
Clear
Taste
Good
Odor
-
Other
-
GENERAL INFORMATION
Well Disinfected?
Y
Well Capped?
Y
50ft From Septic System?
Y
Septic Distance Provided By
Driller Determination
Drilling Process Water Obtained From
Well
Pump Installed By Driller?
N
COMMENTS
Comments
no pump test well was developed by blowing