Skip to Main Content

Driller Report Summary

WELL NUMBER

Well Number
20242894
Driller Tag Number
D0132162
Inspection Tag Number
-
Date Received
11/08/2024

WELL CONTRACTOR

License Number
698
Driller Name
Kenneth Warren Gentry
Rig Operator
STEPHEN KEENER

WELL LOCATION

County Name
WAYNE
Driller Map No.
-
Quad Name
OVILLA
Quad Number
0042SE
Quad Nth
4
Address
2188 BARNETT BRANCH RD
Address Line 2
-
City Name
LAWRENCEBURG
State Name
Tennessee
Zip
38464
Zip Ext
5914
Distance From Landmark (miles)
-
Direction From Landmark
-
Nearest Landmark
-
Latitude
35.3180599
Longitude
-87.5905529

TYPE OF WORK

Date Drill Rig Left Site
08/19/2024
Type of Work
New Well

WELL COMPLETION DATA

Completion Date
08/19/2024
Total Depth (ft-bgs)
223
Depth To Bedrock (ft)
117
Static Level (ft-bgs)
-
Estimated Yield (GPM)
5

WATER-BEARING ZONES

WELL TEST

Tested By
Blowing
Static Level (ft-bgs)
-
Pumping Level (ft-bgs)
-
Test After Hours
-
Test After Mins
-
Test Yield (GPM)
-
Hours Prior to Test
-
Minutes Prior to Test
-

FORMATION LOG

671002 & 3 FOOT CLAY SEAMS AND GRAVEL LENSES
2267CLAY AND GRAVEL
07DRY SILTY SOIL LOTS OF GRAVEL
100117LOTS OF GRAVELK SOME CLAY (WATER)
117180LS DARK HARD
180223LS MEDIUM SOFT MEDIUM
722TIGHT RED CLAY

WELL OWNER INFORMATION

Company Name
-
Owner Name
ANGELA GOBBELL
Address
2188 BARNETT BRANCH RD
Address (Line 2)
-
City
LAWRENCEBURG
State
Tennessee
Zip Code
38464

PROPOSED USE OF WELL

Well Use
Residential

PRIMARY CASING

Diameter (in)
6
Top Set (in-above ground)
12
Primary Casing Depth (ft-bgs)
105
Primary Casing Type
Steel
Wall Thickness
.188
SDR#
-

WELL FINISH

Well Finish
Slotted
From (ft-bgs)
105
To (ft-bgs)
120
Screen Type
-
Slot Size (in)
-
Gravel Pack From (ft-bgs)
95
Gravel Pack To (ft-bgs)
126

BACK FILL MATERIAL

Bentonite310
Cuttings1095

LINER CASING

Type
-
Diameter (in)
-
From (ft-bgs)
-
To (ft-bgs)
-
Packers Installed?
-
Packer 1 Depth (ft-bgs)
-
Packer 2 Depth (ft-bgs)
-

ANTICIPATED WATER QUALITY

Appearance
Clear
Taste
Good
Odor
-
Other
-

GENERAL INFORMATION

Well Disinfected?
Y
Well Capped?
Y
50ft From Septic System?
Y
Septic Distance Provided By
Driller Determination
Drilling Process Water Obtained From
Well
Pump Installed By Driller?
-

COMMENTS

Comments
43632