Skip to Main Content
DataViewer - Division of Water Resources (DWR)
Page Help
Guest
---
Go to Home Page
Driller Report Summary
Back
Print
WELL NUMBER
Well Number
20241478
Driller Tag Number
D0129761
Inspection Tag Number
-
Date Received
06/24/2024
WELL CONTRACTOR
License Number
609
Driller Name
Kenneth D. Presnell
Rig Operator
TOM MORROW
WELL LOCATION
County Name
SEVIER
Driller Map No.
-
Quad Name
RICHARDSON-COVE
Quad Number
0164SW
Quad Nth
5
Address
3622 PITTMAN CENTER RD
Address Line 2
-
City Name
SEVIERVILLE
State Name
Tennessee
Zip
37876
Zip Ext
-
Distance From Landmark (miles)
-
Direction From Landmark
-
Nearest Landmark
-
Latitude
35.7966223
Longitude
-83.4287296
TYPE OF WORK
Date Drill Rig Left Site
05/29/2024
Type of Work
New Well
WELL COMPLETION DATA
Completion Date
05/29/2024
Total Depth (ft-bgs)
205
Depth To Bedrock (ft)
10
Static Level (ft-bgs)
20
Estimated Yield (GPM)
11
WATER-BEARING ZONES
Depth (ft-bgs)
GPM
GPH
Water Quality
120
11
-
clear
WELL TEST
Tested By
Blowing
Static Level (ft-bgs)
-
Pumping Level (ft-bgs)
-
Test After Hours
-
Test After Mins
-
Test Yield (GPM)
-
Hours Prior to Test
-
Minutes Prior to Test
-
FORMATION LOG
Depth from (ft)
Depth to (ft)
Description
0
10
CLAY
10
205
BLUE SHALE
WELL OWNER INFORMATION
Company Name
-
Owner Name
TOM KAVANAGH
Address
548 WINDY RD
Address (Line 2)
-
City
MOUNT JULIET
State
Tennessee
Zip Code
37122
PROPOSED USE OF WELL
Well Use
Residential
PRIMARY CASING
Diameter (in)
6
Top Set (in-above ground)
12
Primary Casing Depth (ft-bgs)
41
Primary Casing Type
Steel
Wall Thickness
.188
SDR#
-
WELL FINISH
Well Finish
Open Hole
From (ft-bgs)
41
To (ft-bgs)
205
Screen Type
-
Slot Size (in)
-
Gravel Pack From (ft-bgs)
-
Gravel Pack To (ft-bgs)
-
BACK FILL MATERIAL
Back Fill Type
From (ft-bgs)
To (ft-bgs)
Bentonite
0
41
LINER CASING
Type
-
Diameter (in)
-
From (ft-bgs)
-
To (ft-bgs)
-
Packers Installed?
N
Packer 1 Depth (ft-bgs)
-
Packer 2 Depth (ft-bgs)
-
ANTICIPATED WATER QUALITY
Appearance
Clear
Taste
-
Odor
-
Other
-
GENERAL INFORMATION
Well Disinfected?
Y
Well Capped?
Y
50ft From Septic System?
Y
Septic Distance Provided By
Property Owner
Drilling Process Water Obtained From
Well
Pump Installed By Driller?
-
COMMENTS
Comments
bottom of casing has a drive shoe