Skip to Main Content
DataViewer - Division of Water Resources (DWR)
Page Help
Guest
---
Go to Home Page
Driller Report Summary
Back
Print
WELL NUMBER
Well Number
20242208
Driller Tag Number
D029977
Inspection Tag Number
-
Date Received
09/09/2024
WELL CONTRACTOR
License Number
1076
Driller Name
Michael Wayne Norman
Rig Operator
MICHAEL NORMAN
WELL LOCATION
County Name
BENTON
Driller Map No.
-
Quad Name
CAMDEN
Quad Number
0020SE
Quad Nth
8
Address
MAPLE DRIVE RD
Address Line 2
-
City Name
CAMDEN
State Name
Tennessee
Zip
38320
Zip Ext
-
Distance From Landmark (miles)
3
Direction From Landmark
SE
Nearest Landmark
Camden
Latitude
36.0222205
Longitude
-88.0727821
TYPE OF WORK
Date Drill Rig Left Site
08/15/2024
Type of Work
New Well
WELL COMPLETION DATA
Completion Date
08/15/2024
Total Depth (ft-bgs)
84
Depth To Bedrock (ft)
-
Static Level (ft-bgs)
-
Estimated Yield (GPM)
20
WATER-BEARING ZONES
Depth (ft-bgs)
GPM
GPH
Water Quality
83
20
-
good
WELL TEST
Tested By
Blowing
Static Level (ft-bgs)
-
Pumping Level (ft-bgs)
-
Test After Hours
-
Test After Mins
-
Test Yield (GPM)
-
Hours Prior to Test
-
Minutes Prior to Test
-
FORMATION LOG
Depth from (ft)
Depth to (ft)
Description
0
70
CHERT & CLAY
70
84
CLEAN CHERT
WELL OWNER INFORMATION
Company Name
-
Owner Name
BRYCE TRAVIS
Address
1255 FLATWOODS RD
Address (Line 2)
-
City
CAMDEN
State
Tennessee
Zip Code
38320
PROPOSED USE OF WELL
Well Use
Residential
PRIMARY CASING
Diameter (in)
6
Top Set (in-above ground)
12
Primary Casing Depth (ft-bgs)
83
Primary Casing Type
Galvanized
Wall Thickness
.188
SDR#
-
WELL FINISH
Well Finish
Open Hole
From (ft-bgs)
83
To (ft-bgs)
84
Screen Type
-
Slot Size (in)
-
Gravel Pack From (ft-bgs)
-
Gravel Pack To (ft-bgs)
-
BACK FILL MATERIAL
Back Fill Type
From (ft-bgs)
To (ft-bgs)
Bentonite
3
10
Cuttings
10
83
LINER CASING
Type
-
Diameter (in)
-
From (ft-bgs)
-
To (ft-bgs)
-
Packers Installed?
-
Packer 1 Depth (ft-bgs)
-
Packer 2 Depth (ft-bgs)
-
ANTICIPATED WATER QUALITY
Appearance
Clear
Taste
Good
Odor
-
Other
-
GENERAL INFORMATION
Well Disinfected?
Y
Well Capped?
Y
50ft From Septic System?
Y
Septic Distance Provided By
Property Owner
Drilling Process Water Obtained From
Public Supply
Pump Installed By Driller?
N
COMMENTS
Comments
-