Skip to Main Content
DataViewer - Division of Water Resources (DWR)
Page Help
Guest
Driller Report Summary
Back
Print
WELL NUMBER
Well Number
20243095
Driller Tag Number
D0124999
Inspection Tag Number
-
Date Received
11/20/2024
WELL CONTRACTOR
License Number
1170
Driller Name
David Anthony Mills
Rig Operator
DAVID MILLS JASON LADD JJ MILLS
WELL LOCATION
County Name
BLEDSOE
Driller Map No.
-
Quad Name
MORGAN-SPRINGS
Quad Number
0110SE
Quad Nth
4
Address
1052 CARL VAUGHN RD
Address Line 2
-
City Name
DAYTON
State Name
Tennessee
Zip
37321
Zip Ext
-
Distance From Landmark (miles)
4
Direction From Landmark
S
Nearest Landmark
Hwy 30 E
Latitude
35.5488801
Longitude
-85.1236138
TYPE OF WORK
Date Drill Rig Left Site
09/04/2024
Type of Work
New Well
WELL COMPLETION DATA
Completion Date
09/04/2024
Total Depth (ft-bgs)
300
Depth To Bedrock (ft)
24
Static Level (ft-bgs)
31
Estimated Yield (GPM)
45
WATER-BEARING ZONES
Depth (ft-bgs)
GPM
GPH
Water Quality
201
15
-
good
218
25
-
good
WELL TEST
Tested By
Blowing
Static Level (ft-bgs)
-
Pumping Level (ft-bgs)
-
Test After Hours
-
Test After Mins
-
Test Yield (GPM)
-
Hours Prior to Test
-
Minutes Prior to Test
-
FORMATION LOG
Depth from (ft)
Depth to (ft)
Description
0
24
OVERBURDEN
24
31
SHALE DARK GRAY
31
70
SS GRAY CASED OUT 2-3 GPM
70
73
VERY SOFT SPOT
73
117
SHALE DARK GRAY
117
201
SS GRAY
201
218
SHALE W/12-15 GPM 201
218
300
SS LIHT GRAY WAT AT 218
WELL OWNER INFORMATION
Company Name
-
Owner Name
SAUL RODRIGUEZ
Address
1052 CARL VAUGHN ROAD
Address (Line 2)
-
City
PIKEVILLE
State
Tennessee
Zip Code
37367
PROPOSED USE OF WELL
Well Use
Irrigation
PRIMARY CASING
Diameter (in)
8
Top Set (in-above ground)
18
Primary Casing Depth (ft-bgs)
40
Primary Casing Type
Steel
Wall Thickness
.188
SDR#
-
WELL FINISH
Well Finish
Open Hole
From (ft-bgs)
40
To (ft-bgs)
300
Screen Type
-
Slot Size (in)
-
Gravel Pack From (ft-bgs)
-
Gravel Pack To (ft-bgs)
-
BACK FILL MATERIAL
Back Fill Type
From (ft-bgs)
To (ft-bgs)
Bentonite
3
10
Cuttings
10
40
LINER CASING
Type
-
Diameter (in)
-
From (ft-bgs)
-
To (ft-bgs)
-
Packers Installed?
-
Packer 1 Depth (ft-bgs)
-
Packer 2 Depth (ft-bgs)
-
ANTICIPATED WATER QUALITY
Appearance
Clear
Taste
Good
Odor
-
Other
Iron
GENERAL INFORMATION
Well Disinfected?
Y
Well Capped?
Y
50ft From Septic System?
Y
Septic Distance Provided By
Driller Determination
Drilling Process Water Obtained From
Public Supply
Pump Installed By Driller?
N
COMMENTS
Comments
set 42 ft 8 in casing no shoe, drilled 8 inch hole to 300 to increase yield
---
Go to Home Page