Skip to Main Content

Driller Report Summary

WELL NUMBER

Well Number
20242136
Driller Tag Number
D0131310
Inspection Tag Number
-
Date Received
08/26/2024

WELL CONTRACTOR

License Number
1078
Driller Name
Christopher Jordan Gilreath
Rig Operator
CLINT FERGE

WELL LOCATION

County Name
HARDEMAN
Driller Map No.
-
Quad Name
SILERTON
Quad Number
0439SE
Quad Nth
4
Address
26075 HIGHWAY 125 N
Address Line 2
-
City Name
HENDERSON
State Name
Tennessee
Zip
38340
Zip Ext
-
Distance From Landmark (miles)
-
Direction From Landmark
-
Nearest Landmark
180 ft N of Silerton Rd
Latitude
35.3069541
Longitude
-88.8636175

TYPE OF WORK

Date Drill Rig Left Site
07/01/2024
Type of Work
New Well

WELL COMPLETION DATA

Completion Date
07/01/2024
Total Depth (ft-bgs)
195
Depth To Bedrock (ft)
-
Static Level (ft-bgs)
45
Estimated Yield (GPM)
10

WATER-BEARING ZONES

WELL TEST

Tested By
Pumping
Static Level (ft-bgs)
45
Pumping Level (ft-bgs)
90
Test After Hours
-
Test After Mins
-
Test Yield (GPM)
10
Hours Prior to Test
-
Minutes Prior to Test
-

FORMATION LOG

015CLAY & SAND
30170GRAY CLAY
170195GRAY SAND
1530SAND

WELL OWNER INFORMATION

Company Name
-
Owner Name
JOHN MAYFIELD
Address
26045 HWY 125 N
Address (Line 2)
-
City
HENDERSON
State
Tennessee
Zip Code
38340

PROPOSED USE OF WELL

Well Use
Residential

PRIMARY CASING

Diameter (in)
4
Top Set (in-above ground)
6
Primary Casing Depth (ft-bgs)
185
Primary Casing Type
Plastic
Wall Thickness
160
SDR#
26

WELL FINISH

Well Finish
Screen
From (ft-bgs)
185
To (ft-bgs)
195
Screen Type
Plastic
Slot Size (in)
0.013
Gravel Pack From (ft-bgs)
175
Gravel Pack To (ft-bgs)
195

BACK FILL MATERIAL

Bentonite010
Cuttings10185

LINER CASING

Type
-
Diameter (in)
-
From (ft-bgs)
-
To (ft-bgs)
-
Packers Installed?
-
Packer 1 Depth (ft-bgs)
-
Packer 2 Depth (ft-bgs)
-

ANTICIPATED WATER QUALITY

Appearance
Clear
Taste
Good
Odor
-
Other
-

GENERAL INFORMATION

Well Disinfected?
Y
Well Capped?
Y
50ft From Septic System?
Y
Septic Distance Provided By
Driller Determination
Drilling Process Water Obtained From
Public Supply
Pump Installed By Driller?
Y

COMMENTS

Comments
-