Skip to Main Content
DataViewer - Division of Water Resources (DWR)
Page Help
Guest
---
Go to Home Page
Driller Report Summary
Back
Print
WELL NUMBER
Well Number
20241792
Driller Tag Number
D0131057
Inspection Tag Number
-
Date Received
07/24/2024
WELL CONTRACTOR
License Number
982
Driller Name
Rodney D. Tatum
Rig Operator
TYSON BARNES
WELL LOCATION
County Name
TIPTON
Driller Map No.
-
Quad Name
MUNFORD
Quad Number
0408NE
Quad Nth
1
Address
720 GRIMES RD
Address Line 2
-
City Name
DRUMMONDS
State Name
Tennessee
Zip
38023
Zip Ext
-
Distance From Landmark (miles)
0.85
Direction From Landmark
NE
Nearest Landmark
intersection of Glen Springs Rd and Grimes Rd
Latitude
35.4849989
Longitude
-89.8738925
TYPE OF WORK
Date Drill Rig Left Site
06/14/2024
Type of Work
New Well
WELL COMPLETION DATA
Completion Date
06/14/2024
Total Depth (ft-bgs)
240
Depth To Bedrock (ft)
-
Static Level (ft-bgs)
102
Estimated Yield (GPM)
60
WATER-BEARING ZONES
Depth (ft-bgs)
GPM
GPH
Water Quality
-
-
-
-
WELL TEST
Tested By
Blowing
Static Level (ft-bgs)
102
Pumping Level (ft-bgs)
-
Test After Hours
1
Test After Mins
-
Test Yield (GPM)
60
Hours Prior to Test
1
Minutes Prior to Test
-
FORMATION LOG
Depth from (ft)
Depth to (ft)
Description
0
5
TOPSOIL
5
40
BROWN CLAY
10
100
COARSE YELLOW SAND
40
50
SAND AND GRAVEL
100
110
WHTIE CLAY
110
115
GRAY SAND
115
145
COARSE GRAY SAND
145
160
GRAY CLAY AND MEDIUM SAND
160
195
MEDIUM SAND
195
200
GRAY CLAY AND MEDIUM SAND
200
240
CORSE GRAY SAND
WELL OWNER INFORMATION
Company Name
-
Owner Name
DALLAS MCLELLAN
Address
720 GRIMES ROAD
Address (Line 2)
-
City
DRUMMONDS
State
Tennessee
Zip Code
38023
PROPOSED USE OF WELL
Well Use
Residential
PRIMARY CASING
Diameter (in)
4
Top Set (in-above ground)
6
Primary Casing Depth (ft-bgs)
180
Primary Casing Type
Plastic
Wall Thickness
40
SDR#
-
WELL FINISH
Well Finish
Screen
From (ft-bgs)
180
To (ft-bgs)
240
Screen Type
Plastic
Slot Size (in)
0.01
Gravel Pack From (ft-bgs)
170
Gravel Pack To (ft-bgs)
240
BACK FILL MATERIAL
Back Fill Type
From (ft-bgs)
To (ft-bgs)
Bentonite
3
10
Cuttings
10
170
LINER CASING
Type
-
Diameter (in)
-
From (ft-bgs)
-
To (ft-bgs)
-
Packers Installed?
-
Packer 1 Depth (ft-bgs)
-
Packer 2 Depth (ft-bgs)
-
ANTICIPATED WATER QUALITY
Appearance
Clear
Taste
Good
Odor
-
Other
-
GENERAL INFORMATION
Well Disinfected?
Y
Well Capped?
Y
50ft From Septic System?
Y
Septic Distance Provided By
Driller Determination
Drilling Process Water Obtained From
Well
Pump Installed By Driller?
N
COMMENTS
Comments
no pump test well was developed by blowing