Skip to Main Content
DataViewer - Division of Water Resources (DWR)
Page Help
Guest
---
Go to Home Page
Driller Report Summary
Back
Print
WELL NUMBER
Well Number
20242193
Driller Tag Number
D0131063
Inspection Tag Number
-
Date Received
09/04/2024
WELL CONTRACTOR
License Number
982
Driller Name
Rodney D. Tatum
Rig Operator
TYSON BARNES
WELL LOCATION
County Name
CHESTER
Driller Map No.
-
Quad Name
LURAY
Quad Number
0446SE
Quad Nth
9
Address
2985 STATE ROUTE 22A
Address Line 2
-
City Name
LURAY
State Name
Tennessee
Zip
38352
Zip Ext
-
Distance From Landmark (miles)
0.23
Direction From Landmark
S
Nearest Landmark
intersection of Dr Young Rd and Hwy 22 A
Latitude
35.5108325
Longitude
-88.5049936
TYPE OF WORK
Date Drill Rig Left Site
06/21/2024
Type of Work
New Well
WELL COMPLETION DATA
Completion Date
06/21/2024
Total Depth (ft-bgs)
180
Depth To Bedrock (ft)
-
Static Level (ft-bgs)
53
Estimated Yield (GPM)
10
WATER-BEARING ZONES
Depth (ft-bgs)
GPM
GPH
Water Quality
-
-
-
-
WELL TEST
Tested By
Blowing
Static Level (ft-bgs)
53
Pumping Level (ft-bgs)
-
Test After Hours
1
Test After Mins
-
Test Yield (GPM)
10
Hours Prior to Test
1
Minutes Prior to Test
-
FORMATION LOG
Depth from (ft)
Depth to (ft)
Description
0
5
TOPSOIL
5
10
BROWN CLAY
10
20
RED SAND
20
60
SAND
60
70
GRAY CLAY
70
110
SAND
110
130
SAND AND WHITE CLAY
130
140
GRAY CLAY
140
180
COARSE SAND
WELL OWNER INFORMATION
Company Name
-
Owner Name
DAN MARSHALL
Address
2985 STATE ROAD 22A
Address (Line 2)
-
City
LURAY
State
Tennessee
Zip Code
38352
PROPOSED USE OF WELL
Well Use
Residential
PRIMARY CASING
Diameter (in)
4
Top Set (in-above ground)
6
Primary Casing Depth (ft-bgs)
170
Primary Casing Type
Plastic
Wall Thickness
40
SDR#
-
WELL FINISH
Well Finish
Screen
From (ft-bgs)
170
To (ft-bgs)
180
Screen Type
Plastic
Slot Size (in)
0.01
Gravel Pack From (ft-bgs)
160
Gravel Pack To (ft-bgs)
180
BACK FILL MATERIAL
Back Fill Type
From (ft-bgs)
To (ft-bgs)
Bentonite
3
10
Cuttings
10
160
LINER CASING
Type
-
Diameter (in)
-
From (ft-bgs)
-
To (ft-bgs)
-
Packers Installed?
-
Packer 1 Depth (ft-bgs)
-
Packer 2 Depth (ft-bgs)
-
ANTICIPATED WATER QUALITY
Appearance
Clear
Taste
Good
Odor
-
Other
-
GENERAL INFORMATION
Well Disinfected?
Y
Well Capped?
Y
50ft From Septic System?
Y
Septic Distance Provided By
Driller Determination
Drilling Process Water Obtained From
Well
Pump Installed By Driller?
N
COMMENTS
Comments
no pump test well was developed by blowing