Skip to Main Content
DataViewer - Division of Water Resources (DWR)
Page Help
Guest
Driller Report Summary
Back
Print
WELL NUMBER
Well Number
20243085
Driller Tag Number
D0132802
Inspection Tag Number
-
Date Received
11/19/2024
WELL CONTRACTOR
License Number
684
Driller Name
Kenneth Keith Walker
Rig Operator
KEITH WALKER
WELL LOCATION
County Name
GRAINGER
Driller Map No.
-
Quad Name
AVONDALE
Quad Number
0162SW
Quad Nth
1
Address
2784 BULLEN VALLEY RD
Address Line 2
-
City Name
THORN HILL
State Name
Tennessee
Zip
37881
Zip Ext
-
Distance From Landmark (miles)
0.25
Direction From Landmark
E
Nearest Landmark
Dalton Cemetery Ln
Latitude
36.3630491
Longitude
-83.4888929
TYPE OF WORK
Date Drill Rig Left Site
10/29/2024
Type of Work
New Well
WELL COMPLETION DATA
Completion Date
10/29/2024
Total Depth (ft-bgs)
260
Depth To Bedrock (ft)
10
Static Level (ft-bgs)
45
Estimated Yield (GPM)
20
WATER-BEARING ZONES
Depth (ft-bgs)
GPM
GPH
Water Quality
235
20
-
clear
WELL TEST
Tested By
Blowing
Static Level (ft-bgs)
-
Pumping Level (ft-bgs)
-
Test After Hours
-
Test After Mins
-
Test Yield (GPM)
20
Hours Prior to Test
-
Minutes Prior to Test
-
FORMATION LOG
Depth from (ft)
Depth to (ft)
Description
0
10
DIRT
10
260
SHELL & SANDSTONE
WELL OWNER INFORMATION
Company Name
-
Owner Name
JENNIFER MONROE
Address
2784 BULLEN VALLEY ROAD
Address (Line 2)
-
City
THORN HILL
State
Tennessee
Zip Code
37881
PROPOSED USE OF WELL
Well Use
Residential
PRIMARY CASING
Diameter (in)
6
Top Set (in-above ground)
12
Primary Casing Depth (ft-bgs)
20
Primary Casing Type
Steel
Wall Thickness
.188
SDR#
-
WELL FINISH
Well Finish
Open Hole
From (ft-bgs)
20
To (ft-bgs)
260
Screen Type
-
Slot Size (in)
6.13
Gravel Pack From (ft-bgs)
-
Gravel Pack To (ft-bgs)
-
BACK FILL MATERIAL
Back Fill Type
From (ft-bgs)
To (ft-bgs)
Bentonite
3
10
Cuttings
10
20
LINER CASING
Type
-
Diameter (in)
-
From (ft-bgs)
-
To (ft-bgs)
-
Packers Installed?
-
Packer 1 Depth (ft-bgs)
-
Packer 2 Depth (ft-bgs)
-
ANTICIPATED WATER QUALITY
Appearance
Clear
Taste
Good
Odor
-
Other
-
GENERAL INFORMATION
Well Disinfected?
Y
Well Capped?
Y
50ft From Septic System?
Y
Septic Distance Provided By
-
Drilling Process Water Obtained From
Well
Pump Installed By Driller?
Y
COMMENTS
Comments
-
---
Go to Home Page