Skip to Main Content
DataViewer - Division of Water Resources (DWR)
Page Help
Guest
---
Go to Home Page
Driller Report Summary
Back
Print
WELL NUMBER
Well Number
20242889
Driller Tag Number
D0132157
Inspection Tag Number
-
Date Received
11/08/2024
WELL CONTRACTOR
License Number
698
Driller Name
Kenneth Warren Gentry
Rig Operator
STEPHEN KEENER
WELL LOCATION
County Name
PERRY
Driller Map No.
-
Quad Name
GRAVES-SPRING
Quad Number
0041SW
Quad Nth
4
Address
349 STARLIGHT DR LOT 184
Address Line 2
-
City Name
LINDEN
State Name
Tennessee
Zip
37096
Zip Ext
-
Distance From Landmark (miles)
-
Direction From Landmark
-
Nearest Landmark
-
Latitude
35.5802952
Longitude
-87.729992
TYPE OF WORK
Date Drill Rig Left Site
08/07/2024
Type of Work
New Well
WELL COMPLETION DATA
Completion Date
08/07/2024
Total Depth (ft-bgs)
263
Depth To Bedrock (ft)
156
Static Level (ft-bgs)
-
Estimated Yield (GPM)
1.5
WATER-BEARING ZONES
Depth (ft-bgs)
GPM
GPH
Water Quality
140
1.5
-
cloudy
WELL TEST
Tested By
Blowing
Static Level (ft-bgs)
-
Pumping Level (ft-bgs)
-
Test After Hours
-
Test After Mins
-
Test Yield (GPM)
1.5
Hours Prior to Test
1
Minutes Prior to Test
-
FORMATION LOG
Depth from (ft)
Depth to (ft)
Description
3
120
CHERT CLAY GRAVEL
120
156
LARGER GRAVEL MIS CLAY SEAMS
156
263
LS LIGHT TO MEDIUM SOLFT
0
3
TREE ROOTS AN DLOOSE MATERIAL
WELL OWNER INFORMATION
Company Name
-
Owner Name
MICHAEL NOEL
Address
750 COMMERCE ST APT 1N
Address (Line 2)
-
City
THORNWOOD
State
New York
Zip Code
-
PROPOSED USE OF WELL
Well Use
Residential
PRIMARY CASING
Diameter (in)
6
Top Set (in-above ground)
12
Primary Casing Depth (ft-bgs)
141
Primary Casing Type
Steel
Wall Thickness
.188
SDR#
-
WELL FINISH
Well Finish
Slotted
From (ft-bgs)
141
To (ft-bgs)
156
Screen Type
-
Slot Size (in)
-
Gravel Pack From (ft-bgs)
131
Gravel Pack To (ft-bgs)
168
BACK FILL MATERIAL
Back Fill Type
From (ft-bgs)
To (ft-bgs)
Bentonite
3
10
Cuttings
10
131
LINER CASING
Type
-
Diameter (in)
-
From (ft-bgs)
-
To (ft-bgs)
-
Packers Installed?
-
Packer 1 Depth (ft-bgs)
-
Packer 2 Depth (ft-bgs)
-
ANTICIPATED WATER QUALITY
Appearance
Clear
Taste
Good
Odor
-
Other
-
GENERAL INFORMATION
Well Disinfected?
Y
Well Capped?
Y
50ft From Septic System?
Y
Septic Distance Provided By
Driller Determination
Drilling Process Water Obtained From
Well
Pump Installed By Driller?
Y
COMMENTS
Comments
43494 replaces D0131970