Skip to Main Content
DataViewer - Division of Water Resources (DWR)
Page Help
Guest
---
Go to Home Page
Driller Report Summary
Back
Print
WELL NUMBER
Well Number
20241795
Driller Tag Number
D0131022
Inspection Tag Number
-
Date Received
07/24/2024
WELL CONTRACTOR
License Number
982
Driller Name
Rodney D. Tatum
Rig Operator
TYSON BARNES
WELL LOCATION
County Name
MADISON
Driller Map No.
-
Quad Name
CLAYBROOK
Quad Number
0446NW
Quad Nth
5
Address
62 COUNTRY CHASE DR
Address Line 2
-
City Name
JACKSON
State Name
Tennessee
Zip
38305
Zip Ext
9029
Distance From Landmark (miles)
0.22
Direction From Landmark
S
Nearest Landmark
intersection of Hwy 412 & Country Chase Rd
Latitude
35.6866644
Longitude
-88.6858308
TYPE OF WORK
Date Drill Rig Left Site
05/28/2024
Type of Work
New Well
WELL COMPLETION DATA
Completion Date
05/28/2024
Total Depth (ft-bgs)
130
Depth To Bedrock (ft)
-
Static Level (ft-bgs)
75
Estimated Yield (GPM)
60
WATER-BEARING ZONES
Depth (ft-bgs)
GPM
GPH
Water Quality
-
-
-
-
WELL TEST
Tested By
Blowing
Static Level (ft-bgs)
75
Pumping Level (ft-bgs)
-
Test After Hours
1
Test After Mins
-
Test Yield (GPM)
60
Hours Prior to Test
1
Minutes Prior to Test
-
FORMATION LOG
Depth from (ft)
Depth to (ft)
Description
0
5
TOPSOIL
5
15
BROWN SAND
15
60
WHOITE SAND
60
110
COARSE WHTE SAND
110
115
GRAY CLAY
110
115
GRAY CLAY
115
120
SAND
120
130
GRAY CLAY
WELL OWNER INFORMATION
Company Name
-
Owner Name
DAVID MCCOY
Address
62 COUNTRY CHASE DRIVE
Address (Line 2)
-
City
JACKSON
State
Tennessee
Zip Code
38305
PROPOSED USE OF WELL
Well Use
Other
PRIMARY CASING
Diameter (in)
4
Top Set (in-above ground)
6
Primary Casing Depth (ft-bgs)
100
Primary Casing Type
Plastic
Wall Thickness
40
SDR#
-
WELL FINISH
Well Finish
Screen
From (ft-bgs)
100
To (ft-bgs)
130
Screen Type
Plastic
Slot Size (in)
0.01
Gravel Pack From (ft-bgs)
90
Gravel Pack To (ft-bgs)
130
BACK FILL MATERIAL
Back Fill Type
From (ft-bgs)
To (ft-bgs)
Bentonite
3
10
Cuttings
10
90
LINER CASING
Type
-
Diameter (in)
-
From (ft-bgs)
-
To (ft-bgs)
-
Packers Installed?
-
Packer 1 Depth (ft-bgs)
-
Packer 2 Depth (ft-bgs)
-
ANTICIPATED WATER QUALITY
Appearance
Clear
Taste
Good
Odor
-
Other
-
GENERAL INFORMATION
Well Disinfected?
Y
Well Capped?
Y
50ft From Septic System?
Y
Septic Distance Provided By
Driller Determination
Drilling Process Water Obtained From
Well
Pump Installed By Driller?
N
COMMENTS
Comments
no pump test well was developed by blowing