Skip to Main Content
DataViewer - Division of Water Resources (DWR)
Page Help
Guest
---
Go to Home Page
Driller Report Summary
Back
Print
WELL NUMBER
Well Number
20242888
Driller Tag Number
D0132156
Inspection Tag Number
-
Date Received
11/08/2024
WELL CONTRACTOR
License Number
698
Driller Name
Kenneth Warren Gentry
Rig Operator
STEPHEN KEENER
WELL LOCATION
County Name
LAWRENCE
Driller Map No.
-
Quad Name
SUMMERTOWN
Quad Number
0051NE
Quad Nth
6
Address
144 OLD HWY 43
Address Line 2
-
City Name
SUMMERTOWN
State Name
Tennessee
Zip
38483
Zip Ext
-
Distance From Landmark (miles)
-
Direction From Landmark
-
Nearest Landmark
-
Latitude
35.4172397
Longitude
-87.2747276
TYPE OF WORK
Date Drill Rig Left Site
08/29/2024
Type of Work
New Well
WELL COMPLETION DATA
Completion Date
08/29/2024
Total Depth (ft-bgs)
97
Depth To Bedrock (ft)
78
Static Level (ft-bgs)
-
Estimated Yield (GPM)
10
WATER-BEARING ZONES
Depth (ft-bgs)
GPM
GPH
Water Quality
57
10
-
clear
WELL TEST
Tested By
Blowing
Static Level (ft-bgs)
-
Pumping Level (ft-bgs)
-
Test After Hours
-
Test After Mins
-
Test Yield (GPM)
10
Hours Prior to Test
1
Minutes Prior to Test
-
FORMATION LOG
Depth from (ft)
Depth to (ft)
Description
0
4
DRY SOIL
4
10
RED CLAY AND SMALL GRAVEL
10
57
CLAY AND GRAVEL
57
78
CLAY GRAVEL (WATER)
78
81
LS
81
86
BROKEN ZONE WITH GRAVEL
86
90
LS
90
93
BROKEN WITH GRAVEL
93
97
LS FRACTOR
WELL OWNER INFORMATION
Company Name
-
Owner Name
URA BYLER
Address
56 MCDOWELL ROAD
Address (Line 2)
-
City
ETHRIDGE
State
Tennessee
Zip Code
38456
PROPOSED USE OF WELL
Well Use
Residential
PRIMARY CASING
Diameter (in)
6
Top Set (in-above ground)
12
Primary Casing Depth (ft-bgs)
77
Primary Casing Type
Plastic
Wall Thickness
-
SDR#
26
WELL FINISH
Well Finish
Screen
From (ft-bgs)
77
To (ft-bgs)
97
Screen Type
Plastic
Slot Size (in)
0.02
Gravel Pack From (ft-bgs)
67
Gravel Pack To (ft-bgs)
97
BACK FILL MATERIAL
Back Fill Type
From (ft-bgs)
To (ft-bgs)
Bentonite
3
10
Cuttings
10
67
LINER CASING
Type
-
Diameter (in)
-
From (ft-bgs)
-
To (ft-bgs)
-
Packers Installed?
-
Packer 1 Depth (ft-bgs)
-
Packer 2 Depth (ft-bgs)
-
ANTICIPATED WATER QUALITY
Appearance
Clear
Taste
Good
Odor
-
Other
-
GENERAL INFORMATION
Well Disinfected?
Y
Well Capped?
Y
50ft From Septic System?
Y
Septic Distance Provided By
Driller Determination
Drilling Process Water Obtained From
Well
Pump Installed By Driller?
N
COMMENTS
Comments
43431