WELL NUMBER
Well Number
20242337
Driller Tag Number
D0131064
Inspection Tag Number
-
Date Received
09/17/2024
WELL CONTRACTOR
License Number
982
Driller Name
Rodney D. Tatum
Rig Operator
TYSON BARNES
WELL LOCATION
County Name
LAUDERDALE
Driller Map No.
-
Quad Name
GATES
Quad Number
0421SW
Quad Nth
1
Address
1477 DRY HILL RD EAST
Address Line 2
-
City Name
GATES
State Name
Tennessee
Zip
38037
Zip Ext
-
Distance From Landmark (miles)
-
Direction From Landmark
-
Nearest Landmark
intersection of Wilson Rd and Dry Hill Rd East
Latitude
35.8372205
Longitude
-89.4794487
TYPE OF WORK
Date Drill Rig Left Site
06/25/2024
Type of Work
New Well
WELL COMPLETION DATA
Completion Date
06/25/2024
Total Depth (ft-bgs)
-
Depth To Bedrock (ft)
-
Static Level (ft-bgs)
75
Estimated Yield (GPM)
35
WATER-BEARING ZONES
Depth (ft-bgs)
GPM
GPH
Water Quality
-
-
-
-
WELL TEST
Tested By
Blowing
Static Level (ft-bgs)
75
Pumping Level (ft-bgs)
-
Test After Hours
1
Test After Mins
-
Test Yield (GPM)
35
Hours Prior to Test
1
Minutes Prior to Test
-
FORMATION LOG
Depth from (ft)
Depth to (ft)
Description
0
5
TOPSOIL
5
35
BROWN CLAY
35
45
SAND AND WHITE CLAY
45
50
GRAVEL
50
70
SAND
70
80
WHITE CLAY
80
100
COARSE SAND
100
120
WHITE CLAY AND COARSE SAND
120
200
COARSE SAND
WELL OWNER INFORMATION
Company Name
-
Owner Name
JOEY GOFORTH
Address
1477 DRY HILL RD EAST
Address (Line 2)
-
City
GATES
State
Tennessee
Zip Code
38037
PROPOSED USE OF WELL
Well Use
Residential
PRIMARY CASING
Diameter (in)
4
Top Set (in-above ground)
6
Primary Casing Depth (ft-bgs)
170
Primary Casing Type
Plastic
Wall Thickness
40
SDR#
-
WELL FINISH
Well Finish
Screen
From (ft-bgs)
170
To (ft-bgs)
200
Screen Type
Plastic
Slot Size (in)
0.01
Gravel Pack From (ft-bgs)
160
Gravel Pack To (ft-bgs)
200
BACK FILL MATERIAL
Back Fill Type
From (ft-bgs)
To (ft-bgs)
Bentonite
3
10
Cuttings
10
160
LINER CASING
Type
-
Diameter (in)
-
From (ft-bgs)
-
To (ft-bgs)
-
Packers Installed?
-
Packer 1 Depth (ft-bgs)
-
Packer 2 Depth (ft-bgs)
-
ANTICIPATED WATER QUALITY
Appearance
Clear
Taste
Good
Odor
-
Other
-
GENERAL INFORMATION
Well Disinfected?
Y
Well Capped?
Y
50ft From Septic System?
Y
Septic Distance Provided By
Driller Determination
Drilling Process Water Obtained From
Well
Pump Installed By Driller?
N
COMMENTS
Comments
no pump test well was developed by blowing NOI received with well report