Skip to Main Content
DataViewer - Division of Water Resources (DWR)
Page Help
Guest
---
Go to Home Page
Driller Report Summary
Back
Print
WELL NUMBER
Well Number
20242831
Driller Tag Number
D0131605
Inspection Tag Number
-
Date Received
11/20/2024
WELL CONTRACTOR
License Number
1014
Driller Name
J. Brandon Allen
Rig Operator
DAN RYMER
WELL LOCATION
County Name
MAURY
Driller Map No.
-
Quad Name
RALLY-HILL
Quad Number
0064NE
Quad Nth
1
Address
3065 HWY 431
Address Line 2
-
City Name
SPRING HILL
State Name
Tennessee
Zip
37174
Zip Ext
-
Distance From Landmark (miles)
-
Direction From Landmark
-
Nearest Landmark
-
Latitude
35.718278
Longitude
-86.82975
TYPE OF WORK
Date Drill Rig Left Site
11/18/2024
Type of Work
Rework
WELL COMPLETION DATA
Completion Date
11/18/2024
Total Depth (ft-bgs)
200
Depth To Bedrock (ft)
1
Static Level (ft-bgs)
40
Estimated Yield (GPM)
125
WATER-BEARING ZONES
Depth (ft-bgs)
GPM
GPH
Water Quality
115
75
-
clear
135
25
-
clear
150
25
-
clear
WELL TEST
Tested By
Blowing
Static Level (ft-bgs)
-
Pumping Level (ft-bgs)
-
Test After Hours
-
Test After Mins
-
Test Yield (GPM)
-
Hours Prior to Test
-
Minutes Prior to Test
-
FORMATION LOG
Depth from (ft)
Depth to (ft)
Description
120
190
BROWN
0
1
DIRT
190
200
GRAY
1
120
GRAY BROWN
WELL OWNER INFORMATION
Company Name
STORIED DEVELOPMENT LLC
Owner Name
Address
1103 RYAN PASS
Address (Line 2)
-
City
ATHENS
State
Georgia
Zip Code
30606
PROPOSED USE OF WELL
Well Use
Irrigation
PRIMARY CASING
Diameter (in)
8
Top Set (in-above ground)
18
Primary Casing Depth (ft-bgs)
20
Primary Casing Type
Steel
Wall Thickness
.188
SDR#
-
WELL FINISH
Well Finish
Open Hole
From (ft-bgs)
20
To (ft-bgs)
200
Screen Type
-
Slot Size (in)
-
Gravel Pack From (ft-bgs)
-
Gravel Pack To (ft-bgs)
-
BACK FILL MATERIAL
Back Fill Type
From (ft-bgs)
To (ft-bgs)
Bentonite
3
10
Cuttings
10
20
LINER CASING
Type
-
Diameter (in)
-
From (ft-bgs)
-
To (ft-bgs)
-
Packers Installed?
N
Packer 1 Depth (ft-bgs)
-
Packer 2 Depth (ft-bgs)
-
ANTICIPATED WATER QUALITY
Appearance
Clear
Taste
-
Odor
Sulphur
Other
-
GENERAL INFORMATION
Well Disinfected?
Y
Well Capped?
Y
50ft From Septic System?
Y
Septic Distance Provided By
Driller Determination
Drilling Process Water Obtained From
Public Supply
Pump Installed By Driller?
N
COMMENTS
Comments
Opened D0125340 up to a 8 on well NOI 39852 2nd rework Corrected well owner business address and lat/long. RAB, DWR 21 Nov 2024