WELL NUMBER
Well Number
20242682
Driller Tag Number
D0127514
Inspection Tag Number
-
Date Received
11/15/2024
WELL CONTRACTOR
License Number
32
Driller Name
Chris Wilson
Rig Operator
MARK BOYER
WELL LOCATION
County Name
WASHINGTON
Driller Map No.
-
Quad Name
LEESBURG
Quad Number
0189SE
Quad Nth
2
Address
2070 HWY 81 N
Address Line 2
-
City Name
JONESBOROUGH
State Name
Tennessee
Zip
37659
Zip Ext
-
Distance From Landmark (miles)
-
Direction From Landmark
-
Nearest Landmark
-
Latitude
36.343884
Longitude
-82.5816605
TYPE OF WORK
Date Drill Rig Left Site
10/03/2024
Type of Work
New Well
WELL COMPLETION DATA
Completion Date
10/03/2024
Total Depth (ft-bgs)
450
Depth To Bedrock (ft)
70
Static Level (ft-bgs)
150
Estimated Yield (GPM)
20
WATER-BEARING ZONES
Depth (ft-bgs)
GPM
GPH
Water Quality
423
20
-
good
WELL TEST
Tested By
Bailing
Static Level (ft-bgs)
-
Pumping Level (ft-bgs)
-
Test After Hours
-
Test After Mins
-
Test Yield (GPM)
-
Hours Prior to Test
1
Minutes Prior to Test
-
FORMATION LOG
Depth from (ft)
Depth to (ft)
Description
0
70
RED CLAY
70
450
SHALE & LIME MIXED
WELL OWNER INFORMATION
Company Name
-
Owner Name
LEE AYERS
Address
240 TIMBER RIDGE RD
Address (Line 2)
-
City
BLUFF CITY
State
Tennessee
Zip Code
37618
PROPOSED USE OF WELL
Well Use
Residential
PRIMARY CASING
Diameter (in)
6
Top Set (in-above ground)
18
Primary Casing Depth (ft-bgs)
-
Primary Casing Type
Steel
Wall Thickness
.188
SDR#
-
WELL FINISH
Well Finish
Open Hole
From (ft-bgs)
217
To (ft-bgs)
450
Screen Type
-
Slot Size (in)
-
Gravel Pack From (ft-bgs)
-
Gravel Pack To (ft-bgs)
-
BACK FILL MATERIAL
Back Fill Type
From (ft-bgs)
To (ft-bgs)
Cement
3
10
Cuttings
10
217
LINER CASING
Type
Steel
Diameter (in)
5.5625
From (ft-bgs)
213
To (ft-bgs)
423
Packers Installed?
Y
Packer 1 Depth (ft-bgs)
0
Packer 2 Depth (ft-bgs)
214
ANTICIPATED WATER QUALITY
Appearance
Clear
Taste
Good
Odor
-
Other
-
GENERAL INFORMATION
Well Disinfected?
Y
Well Capped?
Y
50ft From Septic System?
-
Septic Distance Provided By
Driller Determination
Drilling Process Water Obtained From
Well
Pump Installed By Driller?
-
COMMENTS
Comments
no septic on site 10/03/2024