Skip to Main Content
DataViewer - Division of Water Resources (DWR)
Page Help
Guest
---
Go to Home Page
Driller Report Summary
Back
Print
WELL NUMBER
Well Number
20242333
Driller Tag Number
D0132462
Inspection Tag Number
-
Date Received
09/17/2024
WELL CONTRACTOR
License Number
982
Driller Name
Rodney D. Tatum
Rig Operator
TYSON BARNES
WELL LOCATION
County Name
GIBSON
Driller Map No.
-
Quad Name
MEDINA
Quad Number
0437SE
Quad Nth
6
Address
118 HARGROVE RD
Address Line 2
-
City Name
MEDINA
State Name
Tennessee
Zip
38355
Zip Ext
-
Distance From Landmark (miles)
0.03
Direction From Landmark
N
Nearest Landmark
intersection of Hwy 152 and Roy Hargrove Rd
Latitude
35.8058394
Longitude
-88.7669466
TYPE OF WORK
Date Drill Rig Left Site
08/20/2024
Type of Work
New Well
WELL COMPLETION DATA
Completion Date
08/20/2024
Total Depth (ft-bgs)
240
Depth To Bedrock (ft)
-
Static Level (ft-bgs)
72
Estimated Yield (GPM)
60
WATER-BEARING ZONES
Depth (ft-bgs)
GPM
GPH
Water Quality
-
-
-
-
WELL TEST
Tested By
Blowing
Static Level (ft-bgs)
72
Pumping Level (ft-bgs)
-
Test After Hours
1
Test After Mins
-
Test Yield (GPM)
60
Hours Prior to Test
1
Minutes Prior to Test
-
FORMATION LOG
Depth from (ft)
Depth to (ft)
Description
0
5
TOP SOIL
5
10
BROWN CLAY
10
20
SAND
20
30
WHITE CLAY
30
45
WHITE CLAY AND SAND
45
105
SAND
105
170
GRAY CLAY AND SAND
170
240
COARSE SAND
WELL OWNER INFORMATION
Company Name
-
Owner Name
CRAIG COLTHARP
Address
118 HARGROVE LANE
Address (Line 2)
-
City
MEDINA
State
Tennessee
Zip Code
38355
PROPOSED USE OF WELL
Well Use
Residential
PRIMARY CASING
Diameter (in)
4
Top Set (in-above ground)
6
Primary Casing Depth (ft-bgs)
210
Primary Casing Type
Plastic
Wall Thickness
40
SDR#
-
WELL FINISH
Well Finish
Screen
From (ft-bgs)
210
To (ft-bgs)
240
Screen Type
Plastic
Slot Size (in)
0.01
Gravel Pack From (ft-bgs)
200
Gravel Pack To (ft-bgs)
240
BACK FILL MATERIAL
Back Fill Type
From (ft-bgs)
To (ft-bgs)
Bentonite
3
10
Cuttings
10
200
LINER CASING
Type
-
Diameter (in)
-
From (ft-bgs)
-
To (ft-bgs)
-
Packers Installed?
-
Packer 1 Depth (ft-bgs)
-
Packer 2 Depth (ft-bgs)
-
ANTICIPATED WATER QUALITY
Appearance
Clear
Taste
Good
Odor
-
Other
-
GENERAL INFORMATION
Well Disinfected?
Y
Well Capped?
Y
50ft From Septic System?
Y
Septic Distance Provided By
Driller Determination
Drilling Process Water Obtained From
Well
Pump Installed By Driller?
N
COMMENTS
Comments
no pump test well was developed by blowing