Skip to Main Content

Driller Report Summary

WELL NUMBER

Well Number
20241575
Driller Tag Number
D0131017
Inspection Tag Number
-
Date Received
07/01/2024

WELL CONTRACTOR

License Number
982
Driller Name
Rodney D. Tatum
Rig Operator
TYSON BARNES

WELL LOCATION

County Name
TIPTON
Driller Map No.
-
Quad Name
MASON
Quad Number
0415NE
Quad Nth
4
Address
1759 PEETE RD
Address Line 2
-
City Name
MASON
State Name
Tennessee
Zip
38049
Zip Ext
-
Distance From Landmark (miles)
0.48
Direction From Landmark
E
Nearest Landmark
intersection of Pickens Store Rd & Peete Rd
Latitude
35.4347128
Longitude
-89.6147392

TYPE OF WORK

Date Drill Rig Left Site
04/01/2024
Type of Work
New Well

WELL COMPLETION DATA

Completion Date
04/01/2024
Total Depth (ft-bgs)
350
Depth To Bedrock (ft)
-
Static Level (ft-bgs)
70
Estimated Yield (GPM)
10

WATER-BEARING ZONES

WELL TEST

Tested By
Blowing
Static Level (ft-bgs)
70
Pumping Level (ft-bgs)
-
Test After Hours
1
Test After Mins
-
Test Yield (GPM)
10
Hours Prior to Test
1
Minutes Prior to Test
-

FORMATION LOG

05TOPSOIL
530RED CLAY
3040RED CLAY & SAND
40100WHITE CLAY AND FINE SAND
100116BROWN CLAY
116130COARSE SAND
130170GRAY CLAY
170171ROCK
171190GRAY CLAY
190192ROCK
192213GRAY CLAY
213214ROCK
214295GRAY CLAY
295350COARSE GRAY SAND

WELL OWNER INFORMATION

Company Name
-
Owner Name
JANEA WEST
Address
1759 PEETE RD
Address (Line 2)
-
City
MASON
State
Tennessee
Zip Code
38049

PROPOSED USE OF WELL

Well Use
Residential

PRIMARY CASING

Diameter (in)
4
Top Set (in-above ground)
6
Primary Casing Depth (ft-bgs)
330
Primary Casing Type
Plastic
Wall Thickness
40
SDR#
-

WELL FINISH

Well Finish
Screen
From (ft-bgs)
320
To (ft-bgs)
350
Screen Type
Plastic
Slot Size (in)
0.01
Gravel Pack From (ft-bgs)
310
Gravel Pack To (ft-bgs)
350

BACK FILL MATERIAL

Bentonite310
Cuttings10310

LINER CASING

Type
-
Diameter (in)
-
From (ft-bgs)
-
To (ft-bgs)
-
Packers Installed?
-
Packer 1 Depth (ft-bgs)
-
Packer 2 Depth (ft-bgs)
-

ANTICIPATED WATER QUALITY

Appearance
Clear
Taste
Good
Odor
-
Other
-

GENERAL INFORMATION

Well Disinfected?
Y
Well Capped?
Y
50ft From Septic System?
Y
Septic Distance Provided By
Driller Determination
Drilling Process Water Obtained From
Well
Pump Installed By Driller?
N

COMMENTS

Comments
no pump test well was developed by blowing - PARCEL ID: 084 132 00206 000 2023 - PARCEL Owner: BATTLE DANIEL - PARCEL ID: 084 132 00206 000 2023 - PARCEL Owner: BATTLE DANIEL - PARCEL ID: 084 132 00206 000 2023 - PARCEL Owner: BATTLE DANIEL