Skip to Main Content
DataViewer - Division of Water Resources (DWR)
Page Help
Guest
---
Go to Home Page
Driller Report Summary
Back
Print
WELL NUMBER
Well Number
20242639
Driller Tag Number
BA5267
Inspection Tag Number
-
Date Received
10/30/2024
WELL CONTRACTOR
License Number
855
Driller Name
Herman T. Clark
Rig Operator
HERMAN T CLARK
WELL LOCATION
County Name
BEDFORD
Driller Map No.
-
Quad Name
ROVER
Quad Number
0071NE
Quad Nth
4
Address
382 BUNKER HILL RD
Address Line 2
-
City Name
ROCKVALE
State Name
Tennessee
Zip
37153
Zip Ext
-
Distance From Landmark (miles)
-
Direction From Landmark
-
Nearest Landmark
-
Latitude
35.6967313
Longitude
-86.5993792
TYPE OF WORK
Date Drill Rig Left Site
10/13/2024
Type of Work
Backfill and Abandon
WELL COMPLETION DATA
Completion Date
10/13/2024
Total Depth (ft-bgs)
10
Depth To Bedrock (ft)
-
Static Level (ft-bgs)
0
Estimated Yield (GPM)
-
WATER-BEARING ZONES
Depth (ft-bgs)
GPM
GPH
Water Quality
-
-
-
-
WELL TEST
Tested By
-
Static Level (ft-bgs)
-
Pumping Level (ft-bgs)
-
Test After Hours
-
Test After Mins
-
Test Yield (GPM)
-
Hours Prior to Test
-
Minutes Prior to Test
-
FORMATION LOG
Depth from (ft)
Depth to (ft)
Description
-
-
-
WELL OWNER INFORMATION
Company Name
HERMAN CLARK WATER SYSTEMS
Owner Name
Address
382 BUNKER HILL RD
Address (Line 2)
-
City
ROCKVALE
State
Tennessee
Zip Code
37153
PROPOSED USE OF WELL
Well Use
Unknown
PRIMARY CASING
Diameter (in)
5
Top Set (in-above ground)
-
Primary Casing Depth (ft-bgs)
-
Primary Casing Type
-
Wall Thickness
-
SDR#
-
WELL FINISH
Well Finish
-
From (ft-bgs)
-
To (ft-bgs)
-
Screen Type
-
Slot Size (in)
-
Gravel Pack From (ft-bgs)
-
Gravel Pack To (ft-bgs)
-
BACK FILL MATERIAL
No Data Found
LINER CASING
Type
-
Diameter (in)
-
From (ft-bgs)
-
To (ft-bgs)
-
Packers Installed?
-
Packer 1 Depth (ft-bgs)
-
Packer 2 Depth (ft-bgs)
-
ANTICIPATED WATER QUALITY
Appearance
-
Taste
-
Odor
-
Other
-
GENERAL INFORMATION
Well Disinfected?
Y
Well Capped?
-
50ft From Septic System?
-
Septic Distance Provided By
-
Drilling Process Water Obtained From
-
Pump Installed By Driller?
-
COMMENTS
Comments
no pump or piping, casing left in place and cut below ground level, no liner, 1/2 gal chlorine, backfill: neat cement grout 0-10 2 80 lb bags gravity this was likely a rope and bucket well which has dried up. The casing was cast iron with a bell end up. We backfilled and abandoned just to be sure there would be no risk of ground water contamination with septic installed less than 25 ft away from the well.