Skip to Main Content
DataViewer - Division of Water Resources (DWR)
Page Help
Guest
---
Go to Home Page
Driller Report Summary
Back
Print
WELL NUMBER
Well Number
20243097
Driller Tag Number
D0124997
Inspection Tag Number
-
Date Received
11/20/2024
WELL CONTRACTOR
License Number
1170
Driller Name
David Anthony Mills
Rig Operator
DAVID MILLS & JASON LADD
WELL LOCATION
County Name
BLEDSOE
Driller Map No.
-
Quad Name
PENNINE
Quad Number
0118NW
Quad Nth
4
Address
333 ROBERTS RD
Address Line 2
-
City Name
SPRING CITY
State Name
Tennessee
Zip
37337
Zip Ext
-
Distance From Landmark (miles)
2.5
Direction From Landmark
E
Nearest Landmark
Shut in Gap Rd
Latitude
35.6866623
Longitude
-84.991664
TYPE OF WORK
Date Drill Rig Left Site
08/04/2024
Type of Work
New Well
WELL COMPLETION DATA
Completion Date
08/04/2024
Total Depth (ft-bgs)
200
Depth To Bedrock (ft)
14
Static Level (ft-bgs)
46
Estimated Yield (GPM)
7
WATER-BEARING ZONES
Depth (ft-bgs)
GPM
GPH
Water Quality
49
5
-
good
135
2
-
good
WELL TEST
Tested By
Blowing
Static Level (ft-bgs)
-
Pumping Level (ft-bgs)
-
Test After Hours
-
Test After Mins
-
Test Yield (GPM)
-
Hours Prior to Test
-
Minutes Prior to Test
-
FORMATION LOG
Depth from (ft)
Depth to (ft)
Description
0
14
OVERBURDEN
14
18
SHALE GRAY
18
26
SHALE VERY SOFT
26
48
SS GRAY
49
63
HARD SHALE W/WATER 3-5
63
135
SS GRAY
135
137
FAULTY SPOT W/WATER 2GPM
135
185
SHELL DARK GRAY
185
187
COAL
187
200
SS GRAY
WELL OWNER INFORMATION
Company Name
-
Owner Name
LAWRENCE BOYD, JR
Address
333 ROBERTS LN
Address (Line 2)
-
City
SPRING CITY
State
Tennessee
Zip Code
37337
PROPOSED USE OF WELL
Well Use
Residential
PRIMARY CASING
Diameter (in)
6
Top Set (in-above ground)
12
Primary Casing Depth (ft-bgs)
41
Primary Casing Type
Steel
Wall Thickness
.188
SDR#
-
WELL FINISH
Well Finish
Open Hole
From (ft-bgs)
41
To (ft-bgs)
200
Screen Type
-
Slot Size (in)
-
Gravel Pack From (ft-bgs)
-
Gravel Pack To (ft-bgs)
-
BACK FILL MATERIAL
Back Fill Type
From (ft-bgs)
To (ft-bgs)
Bentonite
3
10
Cuttings
10
41
LINER CASING
Type
-
Diameter (in)
-
From (ft-bgs)
-
To (ft-bgs)
-
Packers Installed?
-
Packer 1 Depth (ft-bgs)
-
Packer 2 Depth (ft-bgs)
-
ANTICIPATED WATER QUALITY
Appearance
Clear
Taste
Good
Odor
-
Other
Iron
GENERAL INFORMATION
Well Disinfected?
Y
Well Capped?
Y
50ft From Septic System?
Y
Septic Distance Provided By
Driller Determination
Drilling Process Water Obtained From
Public Supply
Pump Installed By Driller?
Y
COMMENTS
Comments
set 42 ft casing no shoe