Skip to Main Content

Driller Report Summary

WELL NUMBER

Well Number
20221529
Driller Tag Number
D0124587
Inspection Tag Number
-
Date Received
07/07/2022

WELL CONTRACTOR

License Number
982
Driller Name
Rodney D. Tatum
Rig Operator
TYSON BARNES

WELL LOCATION

County Name
FAYETTE
Driller Map No.
1DX
Quad Name
DANCYVILLE
Quad Number
0423NE
Quad Nth
7
Address
375 AKIN RD
Address Line 2
-
City Name
SOMERVILLE
State Name
Tennessee
Zip
38068
Zip Ext
-
Distance From Landmark (miles)
0.44
Direction From Landmark
S
Nearest Landmark
intersection of Hebrun Dr & Akin Rd
Latitude
352300
Longitude
892213

TYPE OF WORK

Date Drill Rig Left Site
06/28/2022
Type of Work
New Well

WELL COMPLETION DATA

Completion Date
06/28/2022
Total Depth (ft-bgs)
175
Depth To Bedrock (ft)
-
Static Level (ft-bgs)
70
Estimated Yield (GPM)
10

WATER-BEARING ZONES

WELL TEST

Tested By
Blowing
Static Level (ft-bgs)
70
Pumping Level (ft-bgs)
-
Test After Hours
1
Test After Mins
-
Test Yield (GPM)
10
Hours Prior to Test
1
Minutes Prior to Test
-

FORMATION LOG

05topsoil
520brown clay
2030white clay
3060medium grain sand
60175coarse sand

WELL OWNER INFORMATION

Company Name
-
Owner Name
TERESA HENRY
Address
375 AKIN RD
Address (Line 2)
-
City
SOMERVILLE
State
Tennessee
Zip Code
38068

PROPOSED USE OF WELL

Well Use
Residential

PRIMARY CASING

Diameter (in)
4
Top Set (in-above ground)
6
Primary Casing Depth (ft-bgs)
155
Primary Casing Type
Plastic
Wall Thickness
40
SDR#
-

WELL FINISH

Well Finish
Screen
From (ft-bgs)
155
To (ft-bgs)
175
Screen Type
Plastic
Slot Size (in)
0.01
Gravel Pack From (ft-bgs)
145
Gravel Pack To (ft-bgs)
175

BACK FILL MATERIAL

Bentonite310
Cuttings10145

LINER CASING

Type
None
Diameter (in)
-
From (ft-bgs)
-
To (ft-bgs)
-
Packers Installed?
N
Packer 1 Depth (ft-bgs)
-
Packer 2 Depth (ft-bgs)
-

ANTICIPATED WATER QUALITY

Appearance
Clear
Taste
Good
Odor
-
Other
-

GENERAL INFORMATION

Well Disinfected?
Y
Well Capped?
Y
50ft From Septic System?
Y
Septic Distance Provided By
Driller Determination
Drilling Process Water Obtained From
Well
Pump Installed By Driller?
N

COMMENTS

Comments
no pump test well was developed by blowing