Skip to Main Content
DataViewer - Division of Water Resources (DWR)
Page Help
Guest
---
Go to Home Page
Driller Report Summary
Back
Print
WELL NUMBER
Well Number
20243027
Driller Tag Number
D0132471
Inspection Tag Number
-
Date Received
11/18/2024
WELL CONTRACTOR
License Number
982
Driller Name
Rodney D. Tatum
Rig Operator
TYSON BARNES
WELL LOCATION
County Name
HAYWOOD
Driller Map No.
-
Quad Name
JONES
Quad Number
0430NW
Quad Nth
8
Address
1013 STURDIVANT RD
Address Line 2
-
City Name
BROWNSVILLE
State Name
Tennessee
Zip
38012
Zip Ext
-
Distance From Landmark (miles)
1.05
Direction From Landmark
N
Nearest Landmark
intersection of Hwy 76 and Sturdivant Rd
Latitude
35.6577865
Longitude
-89.1900134
TYPE OF WORK
Date Drill Rig Left Site
10/14/2024
Type of Work
New Well
WELL COMPLETION DATA
Completion Date
10/14/2024
Total Depth (ft-bgs)
220
Depth To Bedrock (ft)
-
Static Level (ft-bgs)
65
Estimated Yield (GPM)
10
WATER-BEARING ZONES
Depth (ft-bgs)
GPM
GPH
Water Quality
-
-
-
-
WELL TEST
Tested By
Blowing
Static Level (ft-bgs)
65
Pumping Level (ft-bgs)
-
Test After Hours
1
Test After Mins
-
Test Yield (GPM)
10
Hours Prior to Test
1
Minutes Prior to Test
-
FORMATION LOG
Depth from (ft)
Depth to (ft)
Description
0
5
TOPSOIL
5
15
BROWN CLAY
15
30
RED SAND
30
53
WHITE SAND
53
70
WHITE CLAY
70
120
GRAY CLAY
120
135
FINE GRAY SAND
135
155
FINE SAND AND WHITE CLAY
155
220
COARSE SAND
WELL OWNER INFORMATION
Company Name
-
Owner Name
ROBERT THORNTON
Address
1013 STURDIVANT ROAD
Address (Line 2)
-
City
BROWNSVILLE
State
Tennessee
Zip Code
38012
PROPOSED USE OF WELL
Well Use
Residential
PRIMARY CASING
Diameter (in)
4
Top Set (in-above ground)
6
Primary Casing Depth (ft-bgs)
210
Primary Casing Type
Plastic
Wall Thickness
40
SDR#
-
WELL FINISH
Well Finish
Screen
From (ft-bgs)
210
To (ft-bgs)
220
Screen Type
Plastic
Slot Size (in)
0.01
Gravel Pack From (ft-bgs)
200
Gravel Pack To (ft-bgs)
220
BACK FILL MATERIAL
Back Fill Type
From (ft-bgs)
To (ft-bgs)
Bentonite
3
10
Cuttings
10
200
LINER CASING
Type
-
Diameter (in)
-
From (ft-bgs)
-
To (ft-bgs)
-
Packers Installed?
-
Packer 1 Depth (ft-bgs)
-
Packer 2 Depth (ft-bgs)
-
ANTICIPATED WATER QUALITY
Appearance
Clear
Taste
Good
Odor
-
Other
-
GENERAL INFORMATION
Well Disinfected?
Y
Well Capped?
Y
50ft From Septic System?
Y
Septic Distance Provided By
Driller Determination
Drilling Process Water Obtained From
Well
Pump Installed By Driller?
N
COMMENTS
Comments
no pump test well was developed by blowing